Comparing Brain Images Before and After MRI-upgrade - TimFit Upgrade Study

Sponsor
University Ghent (Other)
Overall Status
Completed
CT.gov ID
NCT03531580
Collaborator
(none)
6
1
1
7
0.9

Study Details

Study Description

Brief Summary

In the Ghent University, an upgrade of the MRI-scanner used for research from Siemens Trio Tim to Siemens Prisma Fit is planned in the near future. As a change of MRI hard- and software might influence brain images, it is necessary to evaluate the images before and after the upgrade.

Condition or Disease Intervention/Treatment Phase
  • Device: Magnetic Resonance Imaging
N/A

Study Design

Study Type:
Interventional
Actual Enrollment :
6 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Other
Official Title:
Brain Images Before and After Upgrade of the MRI-scanner (Siemens Tim TRIO vs Siemens PRISMA FIT) - The TimFit Study
Actual Study Start Date :
Nov 29, 2017
Actual Primary Completion Date :
Jun 30, 2018
Actual Study Completion Date :
Jun 30, 2018

Arms and Interventions

Arm Intervention/Treatment
Experimental: Healthy volunteers

six healthy volunteers: 3 male (age 20-40; 40-60 and 60+) and 3 female (age 20-40; 40-60 and 60+)

Device: Magnetic Resonance Imaging
Brain imaging using magnetic resonance imaging, using several MRI sequences: structural imaging (grey matter, using T1-imaging), cerebral perfusion using arterial spin labeling), functional and effective connectivity (using resting-state functional MRI), white matter tracts (using diffusion imaging), white matter lesions (using Fluid-attenuated inversion recovery MRI (FLAIR)) and microbleeds (using Susceptibility weighted imaging (SWI))

Outcome Measures

Primary Outcome Measures

  1. Change in grey matter volume before versus after MRI-upgrade [7 months, 4 scan sessions of max 1 hour]

  2. Change in cerebral perfusion (ml/100g/min) using Arterial Spin Labeling before versus after MRI-upgrade [7 months, 4 scan sessions of max 1 hour]

  3. Change in arterial transit times before versus after MRI-upgrade [7 months, 4 scan sessions of max 1 hour]

  4. Change in functional connectivity (fc) using Resting State functional MRI before versus after MRI-upgrade [7 months, 4 scan sessions of max 1 hour]

  5. Change in effective connectivity using resting state functional MRI before versus after MRI-upgrade [7 months, 4 scan sessions of max 1 hour]

  6. Change in white matter diffusion before versus after MRI-upgrade [7 months, 4 scan sessions of max 1 hour]

  7. Difference in image quality of FLAIR image before versus after MRI-upgrade [7 months, 4 scan sessions of max 1 hour]

  8. Difference in image quality of SWI image before versus after MRI-upgrade [7 months, 4 scan sessions of max 1 hour]

Eligibility Criteria

Criteria

Ages Eligible for Study:
20 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • Healthy volunteer
Exclusion Criteria:
  • Protheses or artificial implants, no magnetic or metal parts in the body

  • Being pregnant or breastfeeding

  • Having claustrophobia

Contacts and Locations

Locations

Site City State Country Postal Code
1 Ghent University Ghent Belgium 9000

Sponsors and Collaborators

  • University Ghent

Investigators

  • Principal Investigator: Eric Achten, PhD, University Hospital, Ghent

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
University Ghent
ClinicalTrials.gov Identifier:
NCT03531580
Other Study ID Numbers:
  • EC/2017/1103
First Posted:
May 21, 2018
Last Update Posted:
Dec 1, 2021
Last Verified:
Nov 1, 2021
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No

Study Results

No Results Posted as of Dec 1, 2021