NICOM2: Non-Invasive Cardiac Output Monitor in Children

Sponsor
Indiana University (Other)
Overall Status
Completed
CT.gov ID
NCT03869606
Collaborator
(none)
50
1
12
4.2

Study Details

Study Description

Brief Summary

This study will be the first of several studies that establish the value of measuring fluid responsiveness in children undergoing general anesthesia. The first study in this series will determine whether fluid responsiveness, as measured with the NICOM cardiac output monitor in normal children before and after passive leg raising, predicts changes in stroke volume, cardiac output, and blood pressure during the early stages of anesthesia. A second study will determine if early treatment of the fluid responsiveness will prevent the decline in blood pressure that accompanies general anesthesia. If the NICOM monitor permits accurate prediction in normal patients, future studies of pediatric patients undergoing major surgery would be indicated.

The investigators would like to add 25 additional patients who will have the NICOM assessments performed in the pre operative area - Pre anesthesia. General anesthesia may alter the results of the NICOM assessments. The investigators will use these 25 subjects to serve as a comparison/control group.

Condition or Disease Intervention/Treatment Phase
  • Device: NICOM by Cheetah Medical

Detailed Description

Eligible patients will be identified from the surgery schedule and will be contacted by a research team member via phone ahead of their surgery date to inform them of the research study. This call will allow the research team member to answer questions and establish the subject's interest in participation. If interested, or not able to be contacted by phone, patient/family will be approached in the pre-operative area or other private hospital setting. He/she and their parent(s) will have ample time to read the consent and ask any questions regarding the study.

If the subject and his/her parent(s) agree to participate, all standard techniques for general anesthesia compatible with the particular surgical procedure will be employed. Clinical decisions concerning the subject's perioperative care will be made by the anesthesiologist of record.

Cardiac output will be measured with the NICOM cardiac output monitor. The NICOM is a non-invasive monitor using bioreactance, a proprietary technique developed by Cheetah Medical that utilizes delay time shifts to measure stroke volume when an alternating current is passed through the thorax. It requires the placement of four surface electrodes (similar to ECG electrodes) above and below the heart on each side of the patient's chest.

This study will measure cardiac output, stroke volume, and fluid responsiveness (increase in stroke volume > 10%) obtained via passive leg elevation immediately after induction of anesthesia. Adult studies have demonstrated that fifty percent of fasted patients are fluid responsive. The investigators seek to determine the incidence on children.

All decisions concerning clinical care of the subject during the perioperative period will made by the anesthesiologist of record in accordance with accepted standard of care.

  1. The NICOM® electrodes will be applied in proper position in the pre-op area. In pre-op, baseline and passive leg measurements will be recorded using the NICOM®. Electrodes will remain in place and will again be used during the OR NICOM® measurements.

  2. Standard physiologic monitors will be used: non-invasive blood pressure, ECG, pulse oximeter, capnograph (end-tidal carbon dioxide), BIS (bispectral analsysis/depth of anesthesia).

  3. Induction of anesthesia to be determined by the anesthesiologist of record. May be either inhalation or intravenous.

  4. Measurements recorded after application of NICOM electrodes include blood pressure, heart rate, end-tidal carbon dioxide, arterial oxygen saturation, BIS level, stroke volume, cardiac output.

  5. After measurement of baseline cardiorespiratory parameters, passive leg elevation to 45 degrees will be performed.

  6. Cardiorespiratory measurements describe in section d will be repeated after passive leg elevation.

  7. Cardiorespiratory parameters will be measured during the next 60 minutes of anesthesia. This information will be used to determine whether fluid responsive patients require additional intravenous fluids or vasoactive drugs during the course of anesthesia.

The same procedures listed above will be performed Pre-anesthesia in the Pre operative area, while the subject is fully awake.

General anesthesia may alter the results of the NICOM procedures. The investigators will add 25 patients who will be evaluated with the study procedures pre anesthesia as a control/comparison group.

Study Design

Study Type:
Observational
Actual Enrollment :
50 participants
Observational Model:
Case-Control
Time Perspective:
Prospective
Official Title:
A Trial of a Non-Invasive Cardiac Output Monitor to Determine Fluid Responsiveness in Children
Actual Study Start Date :
Apr 1, 2019
Actual Primary Completion Date :
Apr 1, 2020
Actual Study Completion Date :
Apr 1, 2020

Outcome Measures

Primary Outcome Measures

  1. Cardiac Output via NICOM monitor [Pre-Induction and fifteen minutes up to thirty minutes Post-Anesthesia Induction]

    Stroke volume x Heart Rate = Cardiac Output

Eligibility Criteria

Criteria

Ages Eligible for Study:
11 Years to 17 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • Patients 11 to no older than 17 years of age
Exclusion Criteria:
  • severed developmental delay,

  • orthopedic patients with leg injuries

  • injury that would prevent passive leg elevation.

  • severe aortic insufficiency,

  • severe anatomic abnormalities of the thoracic aorta

  • patients with external cardiac pacemakers. close

Contacts and Locations

Locations

Site City State Country Postal Code
1 Riley Hospital for Children Indianapolis Indiana United States 46202

Sponsors and Collaborators

  • Indiana University

Investigators

  • Principal Investigator: Andrew F Stasic, MD, Indiana University School of Medicine

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Andrew Stasic, Associate Professor of Anesthesia, Indiana University
ClinicalTrials.gov Identifier:
NCT03869606
Other Study ID Numbers:
  • 1808715198
First Posted:
Mar 11, 2019
Last Update Posted:
Jul 30, 2020
Last Verified:
Jul 1, 2020
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
Yes
Additional relevant MeSH terms:

Study Results

No Results Posted as of Jul 30, 2020