First in Man Study of Left Atrial Appendage Pulsed Field Ablation Occluder

Sponsor
Hangzhou Dinova EP Technology Co., Ltd (Industry)
Overall Status
Recruiting
CT.gov ID
NCT05731882
Collaborator
(none)
10
2
1
20.5
5
0.2

Study Details

Study Description

Brief Summary

This is the first in man study of E-SeaLATM developed and manufactured by Hangzhou Dinova EP Technology Co., Ltd, which can achieve pulsed field ablation and mechanical closure of the Left Atrial Appendage simultaneously, this study aims to initially verify the safety and efficacy of the device.

Condition or Disease Intervention/Treatment Phase
  • Device: E-SeaLA, CardioPulse PFA system
N/A

Study Design

Study Type:
Interventional
Anticipated Enrollment :
10 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Treatment
Official Title:
First in Man Study to Evaluate Safety and Efficacy of Left Atrial Appendage Pulsed Field Ablation Occluder for Simultaneous Pulsed Field Ablation and Mechanical Closure of the Left Atrial Appendage in Patients With Nonvalvular Atrial Fibrillation
Actual Study Start Date :
Jul 17, 2022
Anticipated Primary Completion Date :
Apr 1, 2023
Anticipated Study Completion Date :
Apr 1, 2024

Arms and Interventions

Arm Intervention/Treatment
Experimental: Catheter ablation+E-SeaLATM

Device: E-SeaLA, CardioPulse PFA system
First, pulmonary vein isolation(PVI) was performed with the novel hex spline PFA ablation catheter( CardioPulseTM PFA system, Hangzhou Dinova EP Technology Co., Ltd), then, pulsed field ablation and mechanical closure of the left atrial appendage were achieved by E-SeaLATM(Hangzhou Dinova EP Technology Co., Ltd) implantation.

Outcome Measures

Primary Outcome Measures

  1. Technical success rate [immediately after the procedure]

    Technical success means that the pulmonary vein and left atrial appendage(LAA) remain electrical isolation 20 minutes after ablation, and the per-device leaks≤ 3 mm after E-SeaLA LAA pulsed field ablation(PFA) occluder implantation.

  2. The incidence of major adverse events (MAEs) related to devices or procedures 3 months after procedure [within 3 months after procedure]

    MAE includes death, myocardial infarction, stroke or transient ischemic attack (TIA), pulmonary vein stenosis, phrenic nerve palsy, systemic embolism, pericarditis, pericardial effusion/cardiac tamponade, atrial esophageal fistula, severe vascular access complications, device migration, and device embolization.

Secondary Outcome Measures

  1. Ablation efficiency including total procedure time, catheter dwell time, total ablation time and total X-ray exposure time [immediately after the procedure]

    Total procedure time (defined as the total time from initial femoral venipuncture to final catheter removal), catheter dwell time (time between the pulsed field ablation catheter entering the left atrium and its withdrawal from the left atrium), total ablation time (including total PVI ablation time, total LAA ablation time), total X-ray exposure time (the total time of X-ray imaging of the catheter).

  2. Left atrial appendage closure rate 12 months after procedure [within 12 months after procedure]

    after occlusion device implantation, no forward or reverse blood flow through the occluder confirmed by ultrasound, residual forward or reverse blood flow at the edge of the occluder ≤3mm, peri-device leaks ≥grade 3)

  3. Incidence of ischemic stroke within 12 months after procedure (event/patient-year). [within 12 months after procedure]

    Ischemic stroke refers to the loss of neurological function caused by transient ischemic attack, cerebral thrombosis or cerebral embolism caused by the lesions of the brain itself and/or systemic blood circulation disorders leading to cerebral blood supply disorders. Ischemic stroke is defined as a modified Rankin score (mRS) ≥2 90 days after stroke onset.

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 80 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  1. The age of the patient is 18~80 years old;

  2. patients diagnosed with non-valvular atrial fibrillation (at least 1 episode of atrial fibrillation recorded on ECG or Holter in the 12 months prior to enrollment);

  3. CHA2DS2-VASC score: male≥ 2, female≥ 3;

  4. patients are not suitable for long-term oral anticoagulant therapy (any of the following): (1) not suitable for long-term standardized anticoagulation therapy; (2) stroke or embolism still occurs on the basis of long-term standardized anticoagulation therapy; (3) HAS-BLED score≥ 3 points; (4) need to be treated with antiplatelet drugs; (5) unwillingness to undergo long-term anticoagulant therapy;

  5. Be able to understand the purpose of the study, voluntarily participate in the study, sign the informed consent form by the subject himself or her legal representative, and be willing to complete the follow-up in accordance with the requirements of the program.

Exclusion Criteria:
  1. Atrial fibrillation secondary to electrolyte imbalances, thyroid disease or other reversible factors;

  2. Left atrial appendage depth < 15mm, left atrial appendage anchor area < 10mm or >33mm;

  3. Left atrial diameter≥ 65mm;

  4. Imaging examination shows left atrium or left atrial appendage thrombosis;

  5. Severe structural heart disease (such as moderate to severe aortic valve, mitral stenosis or regurgitation);

  6. Left ventricular ejection fraction <35%, or New York College of Cardiology class III or IV;

  7. Refractory hypertension (blood pressure persists > 180/110mmHg after treatment);

  8. Patients with previous patent foramen ovale closure, atrial septal defect closure or repair;

  9. Patients with previous left atrial appendage occlusion or left atrial appendage closure;

  10. Patients with previous valve repair, prosthetic valve implantation or replacement;

  11. Patients who have implanted devices such as implantable cardioverter defibrillator(ICD), cardiac resynchronization therapy(CRT) or pacemaker or have an implantation plan within 12 months after procedure;

  12. Patients with clinically symptomatic carotid artery stenosis, or patients who have undergone carotid stenting or carotid endarterectomy in the past 6 months;

  13. Patients with a history of myocardial infarction in the past 6 months, or who have undergone coronary artery bypass grafting or percutaneous coronary intervention;

  14. Recorded thromboembolic events (including transient ischemic attack) in the past 30 days;

  15. Serum creatinine greater than 2 times the upper limit of normal, or history of renal dialysis;

  16. Acute systemic infection;

  17. Severe lung disease, pulmonary hypertension or any lung disease involving abnormal blood gases or severe breathing difficulties;

  18. Presence of wall thrombosis, tumors or other abnormalities that interfere with vascular puncture or catheter operation;

  19. Female patients who are pregnant, lactating, or unable to use contraception during the study;

  20. patients have participated in clinical trials of other drugs or devices during the same period;

  21. patient's life expectancy is less than 12 months;

  22. Abnormalities or diseases that the investigator believes should be excluded from the scope of enrollment in this study.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Fuwai Hospital, Chinese Academy of Medical Sciences Beijing Beijing China
2 Fuwai Central China Cardiovascular Hospital Zhengzhou Henan China

Sponsors and Collaborators

  • Hangzhou Dinova EP Technology Co., Ltd

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Hangzhou Dinova EP Technology Co., Ltd
ClinicalTrials.gov Identifier:
NCT05731882
Other Study ID Numbers:
  • E-SeaLA FIM 01
First Posted:
Feb 16, 2023
Last Update Posted:
Feb 16, 2023
Last Verified:
Feb 1, 2023
Individual Participant Data (IPD) Sharing Statement:
Undecided
Plan to Share IPD:
Undecided
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Feb 16, 2023