SP12: Observational Study of the Use of DBLG1 System in Real Life

Sponsor
Diabeloop (Industry)
Overall Status
Active, not recruiting
CT.gov ID
NCT04749693
Collaborator
(none)
348
19
25.9
18.3
0.7

Study Details

Study Description

Brief Summary

This study will be conducted on human subjects and is observational, prospective and uncontrolled, defined as a category 3 according to the Jardé Law (RIPH3). It is a national and multicentric study. Enrolled patients are Type 1 Diabetes (T1D) patients who receive the DBLG1 System (CE marked medical device) to be treated. Patients have their regular visits with their own clinician. No change from their usual care must and will be done, including trainings and treatment. At the end of the study, patients will keep their system for their usual care and will continue having usual follow-up visits with their clinician.

Data related to their glycemia, complications and quality of life will be collected for 1 year from the beginning of their treatment. A comparison with data collected during the 2 weeks of run-in period, prior to the activation of loop mode, is planned. In case the run-in phase lasts longer than 2 weeks, data collected from the two last weeks only will be kept for analysis and comparison.

The study is completed when all patients have their "end of study" file completed in the electronic Case Report Form (eCRF).

Condition or Disease Intervention/Treatment Phase
  • Device: DBLG1 System

Detailed Description

The study is designed to address the specific requirements from National Commission for the Evaluation of Medical Devices and Health Technologies (CNEDiMTS) and to complete data obtained up to now, with a larger cohort and in real life settings.

In order to increase variability in the profiles of patients included and to be as representative as possible of all eligible patients, 20 centers will participate in the study, both private and public, with a mix of university and regional centers and 348 patients will be included consecutively.

The inclusion period lasts 6 months and each patient will be included in the study for a period of 2 weeks of run-in and 1 year of treatment. An inclusion period of 6 months is enough according to investigation site data and estimation of inclusion over 6 months (detailed in part Healthcare professional and investigation centers recruitment).

This study is observational. Patients included follow their usual medical care and will only be asked for the specific need of the study to answer two questionnaires (at the beginning and at the end of the study) and give their HbA1c results performed in their current medical follow-up. As it is a post-registration study, medical devices are provided to patients on medical prescription by healthcare providers, which have signed a distribution agreement with and have been trained by Diabeloop. Patients have their system for 4 a maximum of 4 years (life duration of the medical device (DBLG1 System)).

Patients follow-up visits are not mandatory and no frequency is imposed. Investigators, according to their habits, have follow-up visits corresponding to what they usually propose to patients having a new treatment.

During the whole study and apart from scheduled visits (inclusion, beginning of run-in, beginning of treatment , enf of study), each patient may contact his/her clinician investigator in case of issue he/she judges as serious, for questions, etc. In that case, the clinician may program a visit with the patient and deal with adverse events. Phone calls are recorded in Case Report Form (CRF), as well as on-site visits.

Note: with Yourloops; investigators may follow the state of their patients, regarding the time in range, mean glycemia value etc. Based on this, they may require a visit at their convenience with the patient in order to change parameters of the system, discuss adverse events, etc.

Objectives are the following To evaluate improvement in blood glucose control with use of DBLG1 System after one year in real life.

To evaluate details of glycemic control improvement, safety and adverse events due to the DBLG1 System, evolution of quality of life after one year in real life and healthcare professional support.

Study endpoints Improvement of the time in glycemic range 70 - 180 mg/dL, in percentage, on 24hours and nighttime.

HbA1c Mean CGM glucose - on 24hours and nighttime Time in 70 - 140 mg/dL range on 24hours and nighttime only Time in hypoglycemia (under 70 mg/dL, 60 mg/dL and 50 mg/dL) - on 24hours and nighttime Time in hyperglycemia (above 180 mg/dL, 250 mg/dL and 300 mg/dL) - on 24hours and nighttime Percentage of time using activated loop mode vs. deactivated loop mode Standard Deviation (SD) and Coefficient of variation (CV) of Continuous Glucose Monitoring (CGM) values on 24hours and nighttime Number and type of adverse events Overall and diabetic-specific quality of life Quantification of the healthcare professional support required

An descriptive interim analysis will be made on the first 100 enrolled patients after 6 months of use of the DBLG1.

Study Design

Study Type:
Observational
Anticipated Enrollment :
348 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
Observational Study of the Use of DBLG1 System in Real Life
Actual Study Start Date :
May 17, 2021
Anticipated Primary Completion Date :
Jan 15, 2023
Anticipated Study Completion Date :
Jul 15, 2023

Arms and Interventions

Arm Intervention/Treatment
Patient with HbA1c >= 8% despite the use of insulin pump and frequent glycemic control

only group included in the study

Device: DBLG1 System
Use of DBLG1 System in real life condition

Outcome Measures

Primary Outcome Measures

  1. time in 70 - 180 mg/dL glycemic range [through study completion, an average of 1 year]

    Improvement of the time in glycemic range 70 - 180 mg/dL, in percentage, on 24hours and nighttime

Secondary Outcome Measures

  1. HbA1c HbA1c HbA1c [at the beginning and at the end of the study (1 year between each value)]

    change in the HbA1c after 1 year of use of the device

  2. mean CGM [through study completion, an average of 1 year]

    change of mean CGM glucose on 24hours and nighttime

  3. time in 70 - 140 mg/dL glycemic range [through study completion, an average of 1 year]

    change of time in 70 - 140 mg/dL range on 24hours and nighttime

  4. time in hypoglycemia [through study completion, an average of 1 year]

    change of time in hypoglycemia, under 70 mg/dL, 60 mg/dL and 50 mg/dL on 24hours and nighttime

  5. time in hyperglycemia [through study completion, an average of 1 year]

    change of time in hyperglycemia above 180 mg/dL, 250 mg/dL and 300 mg/dL on 24hours and nighttime

  6. use of loop mode [treatment period, an average of 1 year]

    percentage of time using activated loop mode vs. deactivated loop mode

  7. SD and CV of CGM values [through study completion, an average of 1 year]

    change of SD and CV of CGM values on 24hours and nighttime

  8. adverse event [through study completion, an average of 1 year]

    number of adverse events

  9. Health Survey [at the beginning and at the end of the study (1 year between each value)]

    change of the patient health, evaluated by questionnaire Short Form 12 Health Survey filled in at the beginning and at the end of the study

  10. Fear of hypoglycemia [at the beginning and at the end of the study (1 year between each value)]

    change of the patient fear of hypoglycemia, evaluated by questionnaire Hypoglycemia fear survey filled in at the beginning and at the end of the study

  11. Patient stress status [at the beginning and at the end of the study (1 year between each value)]

    change of the patient stress status, evaluated by questionnaire Diabetes distress scale, filled in at the beginning and at the end of the study

  12. Acceptability of the device [at the beginning and at the end of the study (1 year between each value)]

    change of the patient's satisfaction of previous vs. DBLG1 System devices, evaluated by questionnaire patient stress status, filled in at the beginning and at the end of the study

  13. incidence of the system on the necessary healthcare professional charge [through study completion, an average of 1 year]

    questionnaire at each visit (duration and type of visit, number and type of healthcare professional required for the visit)

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • patients with type 1 diabetes;

  • patients who are at least 18 years old;

  • patients total daily dose required must be less than 90 units (U);

  • patients accepting to be treated with 100 U/mL rapid-acting insulin analog

  • patients having a HbA1c ≥ 8% despite of the use of a pump for at least 6 months

  • patients performing glucose self-monitoring several times ( ≥ 4) a day

  • patient accepting the technology

  • patients agreeing to use the system with activated loop mode during at least 75% of the

  • total time of use, this will be analyzed after 1 year of use.

  • patients must be affiliated to any kind of social security

Exclusion Criteria:
  • patients receiving a total daily dose of insulin lower than 8 U;

  • patients suffering from a serious illness or having a treatment that might significantly impair diabetes physiology (iSGLT2, steroids, metformin), i.e. glucose-insulin interactions, that might interfere with the medical device (for example treatment by steroids with variable dosage during the study period);

  • patients having severe uncorrected problems of hearing and/or visual acuity preventing proper use of DBLG1 System;

  • patients unable to understand and perform all of the instructions regarding the devices and the clinical investigation provided by Diabeloop.

  • patients planning to perform during the year of study repeated magnetic resonance imaging (MRI), computed tomography (CT) scan, or high-frequency electrical heat (diathermy) treatment. The G6 has not been tested in those situations. The magnetic fields and heat could damage the components of the Dexcom G6, which may cause it to display inaccurate sensor glucose readings (readings) or may prevent alerts. Without G6 readings or alarm/alert notifications, patients might be exposed to severe low or high glucose events;

  • patients who are unwilling or unable to maintain contact with the healthcare professional;

  • patients willing to use any insulin that is not 100 U/mL rapid-acting insulin analog with the system (for example regular insulin; long-acting insulin analog; 200 U/mL rapid-acting insulin analog)

Contacts and Locations

Locations

Site City State Country Postal Code
1 Hôpital Avicenne APHP Bobigny France 93000
2 Hôpital de la cavale blanche Brest France 29200
3 CHU Caen Caen France 14000
4 Centre Hospitalier Sud Francilien Corbeil-Essonnes France 91100
5 CHU Bocage Central Dijon France 21079
6 Hôpital Simone Veil Eaubonne France 95600
7 CHU Grenoble Grenoble France 38000
8 Groupe Hospitalier La Rochelle - Ré - Aunis La Rochelle France 17019
9 CHU Lille Lille France 59037
10 Diab-e-Care Lyon France 69008
11 Hôpital la conception, pole ENDO Marseille France 13385
12 hôpital Nord Laennec Nantes France 44093
13 Lariboisière - Fernand Widal APHP Paris France 75010
14 Hôpital Bichet Claude Bernard - APHP Paris France 75018
15 Clinique Princess Pau France 64000
16 CHU Reims Reims France 51100
17 Hôpital Pontchaillou Rennes France 35000
18 Hôpital civil de Strasbourg Strasbourg France 67000
19 Hôpital de Rangueil Toulouse France 31400

Sponsors and Collaborators

  • Diabeloop

Investigators

  • Principal Investigator: Pauline Schaepelynck, APHM Hôpital Sud Sainte Marguerite
  • Principal Investigator: Lucy Chaillous, CHU Nantes
  • Principal Investigator: Hélène Hanaire, CHU Toulouse
  • Principal Investigator: Sandrine Lablanche, University Hospital, Grenoble
  • Principal Investigator: Alfred Penfornis, CH Sud Francilien
  • Principal Investigator: Yves Reznik, CHU Caen

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Diabeloop
ClinicalTrials.gov Identifier:
NCT04749693
Other Study ID Numbers:
  • RCB 2020-A 02808-31
First Posted:
Feb 11, 2021
Last Update Posted:
Mar 11, 2022
Last Verified:
Mar 1, 2022
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by Diabeloop
Additional relevant MeSH terms:

Study Results

No Results Posted as of Mar 11, 2022