Optimal Head Rotation and External Landmark for Internal Jugular Vein Cannulation After Placement of Proseal Laryngeal Mask Airway

Sponsor
Samsung Medical Center (Other)
Overall Status
Completed
CT.gov ID
NCT01407302
Collaborator
(none)
100
1
17.1
5.9

Study Details

Study Description

Brief Summary

Recently, laryngeal mask airway (LMA) placements are frequently performed for general anesthesia. The investigators occasionally encounter a clinical situation to perform internal jugular vein (IJV) cannulation after LMA insertion, especially for difficult airway in subjects undergoing major surgery. However, anatomic relations of IJV and common carotid artery (CCA) in patient with LMA placement have been reported to be different from those in patients with endotracheal tube. The degree of overlapping of the right IJV and CCA after LMA placement was greater than before LMA placement. Furthermore, there are many cases of complete overlapping right IJV and CCA after LMA placement. Therefore, the risk of puncturing CCA increases when the investigators try to cannulate IJV after LMA placement. Furthermore, the central landmark commonly used for IJV cannulation was proved to show low success rate after LMA placement in previous report.

The investigators carefully examined the anatomic relations of IJV and CCA after LMA insertion with ultrasonography, and found that the degree of overlapping is different according to the degree of head rotation. The investigators postulated that if the degree of overlapping is different according to the degree of head rotation after LMA insertion, the investigators can find the angle of head rotation for least overlapping and reduce the risk of CCA puncture. Therefore, the investigators tried (1) to find the optimal head rotation angle appropriate for puncturing IJV after LMA placement, and (2) to find suitable landmark adequate for IJV cannulation after LMA placement.

Condition or Disease Intervention/Treatment Phase
  • Other: Head rotation

Detailed Description

Recently, laryngeal mask airway (LMA) placements are frequently performed for general anesthesia. The investigators occasionally encounter a clinical situation to perform internal jugular vein (IJV) cannulation after LMA insertion, especially for difficult airway in subjects undergoing major surgery. However, anatomic relations of IJV and common carotid artery (CCA) in patient with LMA placement have been reported to be different from those in patients with endotracheal tube. The degree of overlapping of the right IJV and CCA after LMA placement was greater than before LMA placement. Furthermore, there are many cases of complete overlapping right IJV and CCA after LMA placement. Therefore, the risk of puncturing CCA increases when the investigators try to cannulate IJV after LMA placement. Furthermore, the central landmark commonly used for IJV cannulation was proved to show low success rate after LMA placement in previous report. Previous study recommended the lower puncture point near that area where the clavicular head of the sternocleidomastoid muscle attaches to the clavicle, because CCA was not observed in the vicinity of the IJV after LMA insertion. Even though they performed test puncture at the lower puncture point in 20 patients and found no complications, the lower puncture point is not the usual site for IJV cannulation for most anesthesiologists. It is known that increased head rotation is associated with high probability of CCA contact. The investigators carefully examined the anatomic relations of IJV and CCA after LMA insertion with ultrasonography, and found that the degree of overlapping is different according to the degree of head rotation. The investigators postulated that if the degree of overlapping is different according to the degree of head rotation after LMA insertion, the investigators can find the angle of head rotation for least overlapping and reduce the risk of CCA puncture. Therefore, the investigators tried (1) to find the optimal head rotation angle appropriate for puncturing IJV after LMA placement, and (2) to find suitable landmark adequate for IJV cannulation after LMA placement.

Study Design

Study Type:
Observational
Actual Enrollment :
100 participants
Observational Model:
Case-Control
Time Perspective:
Prospective
Official Title:
Optimal Head Rotation and External Landmark for Internal Jugular Vein Cannulation After Placement of Proseal Laryngeal Mask Airway
Study Start Date :
Jul 1, 2011
Actual Primary Completion Date :
Dec 1, 2012
Actual Study Completion Date :
Dec 1, 2012

Arms and Interventions

Arm Intervention/Treatment
LMA group

patients undergoing general anesthesia with LMA insertion

Other: Head rotation
Repeated ultrasonographic examination according to the degree of head rotation (examination of overlap index of internal jugular vein and common carotid artery, and accuracy of external landmark of jugular cannulation)

E-tube group

patients undergoing general anesthesia with e-tube

Other: Head rotation
Repeated ultrasonographic examination according to the degree of head rotation (examination of overlap index of internal jugular vein and common carotid artery, and accuracy of external landmark of jugular cannulation)

Outcome Measures

Primary Outcome Measures

  1. overlap index [at 5 min after anesthesia induction]

    The overlap index was derived from the ratio of the overlapping length of the IJV to the horizontal diameter of the CCA measured on the ultrasonographic image. The formula of calculation is as follows: overlap index = [overlap length (mm)/ CCA diameter (mm)] X 100(%), the measurements were repeated according to the degree of head rotation (neutral, 15 degree, 30 degree, 45 degree)

Secondary Outcome Measures

  1. The success of simulated internal jugular vein puncture (central landmark) [at 5 min after anesthesia induction]

    The success of internal jugular vein puncture guided by the central landmark simulated on the ultrasonographic images, the measurements were repeated according to the degree of head rotation (neutral, 15 degree, 30 degree, 45 degree)

  2. The success of simulated internal jugular vein puncture (external jugular vein landmark) [at 5 min after anesthesia induction]

    The success of internal jugular vein puncture as guided by 1.5 cm or 2.5 cm medial to the external jugular vein simulated on the ultrasonographic images, the measurements were repeated according to the degree of head rotation (neutral, 15 degrees, 30 degrees, 45 degrees)

Eligibility Criteria

Criteria

Ages Eligible for Study:
20 Years to 70 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • patients undergoing general anesthesia with laryngeal mask airway insertion
Exclusion Criteria:
  • patients undergoing emergency surgery

  • patients with anatomical problem of airway

  • anticipated difficult airway

  • patients with hemodynamic unstability

  • patients with severe cardiopulmonary disease

Contacts and Locations

Locations

Site City State Country Postal Code
1 Samsung Medical Center Seoul Korea, Republic of 135-710

Sponsors and Collaborators

  • Samsung Medical Center

Investigators

  • Principal Investigator: Mi Sook Gwak, M.D.,Ph.D., Samsung Medical Center

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Gwak Mi Sook, Professor, Samsung Medical Center
ClinicalTrials.gov Identifier:
NCT01407302
Other Study ID Numbers:
  • 2011-04-024
First Posted:
Aug 2, 2011
Last Update Posted:
Dec 25, 2013
Last Verified:
Dec 1, 2013
Keywords provided by Gwak Mi Sook, Professor, Samsung Medical Center

Study Results