OPTiMASK: Comparison of Pre-oxygenation With Standard Face Mask Combined With High Flow Nasal Oxygen With Pre-oxygenation With Standard Face Mask Alone

Sponsor
Beth Israel Deaconess Medical Center (Other)
Overall Status
Not yet recruiting
CT.gov ID
NCT05495841
Collaborator
(none)
80
1
40.4
2

Study Details

Study Description

Brief Summary

This is an observational, prospective study of patients undergoing a surgical procedure. Three parallel studies are taking place with collaborators in other countries. This study aims to bring novel insights regarding the benefits of pre-oxygenation combining standard oxygen facemask with high-flow nasal oxygen (HFNO), as opposed to standard oxygen facemask alone by assessing end-tidal oxygen (ETO2) levels after intubation.

Condition or Disease Intervention/Treatment Phase
  • Device: Pre-oxygenation

Detailed Description

This is an observational, prospective study of patients undergoing a surgical procedure. A total of 80 patients will be enrolled at BIDMC. Patients meeting inclusion criteria with no exclusions will be approached for consent. 40 patients receiving the pre-oxygenation face mask alone method during clinical routine and 40 patients using the pre-oxygenation combined facemask + HFNO technique as part of routine clinical care will be studied. No randomization will be employed. Choice of pre-oxygenation approach is at the discretion of the clinician. Patients will be enrolled as a convenience sample, such that the first 40 patients will be those with face mask alone, and the second 40 will be patients with face mask + HFNO. Research assistants will discuss the pre-oxygenation plan with the anesthesiologist as part of the screening process. Data will be collected including EtO2 levels during two minutes following intubation.

Methodology

  1. Face mask alone: As per clinical standard, the standard oxygen facemask will be tightly applied on the face of the patient at 100% FiO2 for 3 to 4 minutes. In case of suspected full stomach, it is recommended to perform a rapid sequence induction and the patient does not receive bag-mask ventilation during the apnea period (45-60s). In the other case, a standard pre-oxygenation will be performed (see figure 1: experimental design of the study).

  2. Face mask + Nasal cannula: As to clinical standards, the standard oxygen facemask will be tightly applied on the face of the patient at 100% FiO2 for 3 to 4 minutes and HFNO at 100% with a flow at 40 L/minutes during the pre-oxygenation (the flow can be decreased to less than 40 L/minutes if no tolerance by the patient). Then, after a general anesthesia induction and/or a rapid sequence induction is performed, the patient receives HFNO at 100% FiO2 and the flow of HFNO is increased to up to 80 L/minutes (which corresponds to a close delivered FiO2 at 80%) during the apnea period (1 to 2 min) until correct position of the endotracheal tube is confirmed with capnography.

Assessments The study does not require any research procedures other than passive data collection. For this study, EtO2 levels will be recorded at more frequent intervals than what is entered in the anesthesia record. Therefore, study staff will collect these data from the anesthesia machine in the operating room, where values are displayed on a breath-by-breath basis

Study Design

Study Type:
Observational
Anticipated Enrollment :
80 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
OPTiMASK: Comparison of Pre-oxygenation With Standard Face Mask Combined With High Flow Nasal Oxygen With Pre-oxygenation With Standard Face Mask Alone
Anticipated Study Start Date :
Aug 18, 2022
Anticipated Primary Completion Date :
Dec 30, 2024
Anticipated Study Completion Date :
Dec 30, 2025

Arms and Interventions

Arm Intervention/Treatment
Face Mask Alone

40 patients receiving the pre-oxygenation face mask alone method during clinical routine will be studied. As per clinical standard, the standard oxygen facemask will be tightly applied on the face of the patient at 100% FiO2 for 3 to 4 minutes. In case of suspected full stomach, it is recommended to perform a rapid sequence induction and the patient does not receive bag-mask ventilation during the apnea period (45-60s). In the other case, a standard pre-oxygenation will be performed (see figure 1: experimental design of the study).

Device: Pre-oxygenation
Process of administrating oxygen prior to intubation

Face Mask and Nasal Cannula

40 patients using the pre-oxygenation combined facemask + HFNO technique as part of routine clinical care will be studied. As to clinical standards, the standard oxygen facemask will be tightly applied on the face of the patient at 100% FiO2 for 3 to 4 minutes and HFNO at 100% with a flow at 40 L/minutes during the pre-oxygenation (the flow can be decreased to less than 40 L/minutes if no tolerance by the patient). Then, after a general anesthesia induction and/or a rapid sequence induction is performed, the patient receives HFNO at 100% FiO2 and the flow of HFNO is increased to up to 80 L/minutes (which corresponds to a close delivered FiO2 at 80%) during the apnea period (1 to 2 min) until correct position of the endotracheal tube is confirmed with capnography.

Device: Pre-oxygenation
Process of administrating oxygen prior to intubation

Outcome Measures

Primary Outcome Measures

  1. Lowest EtO2 value [start of intubation to 2 minutes after]

    Lowest EtO2 value within the two minutes following tracheal intubation

Secondary Outcome Measures

  1. SpO2 at the start and at the end of the procedure [start of intubation to 4 minutes after]

    SpO2 at the start and at the end of the procedure and EtO2 each minute during the four minutes of pre-oxygenation

  2. Tolerance of the device [entirety of procedure]

    Tolerance of the device (discomfort considered if the patient asks for reduction of the gas flow of HFNC: Yes or No

  3. Lowest SpO2 [start of intubation to 2 minutes after]

    Lowest SpO2 during intubation and within 2 min after intubation

  4. Highest level of EtCO2 [start of intubation to 2 minutes after]

    Highest level of EtCO2 within 2 min following intubation

  5. Rate of oxygen desaturation [entirety of procedure]

    Rate of oxygen desaturation below 95% during the procedure

  6. Number of laryngoscopy attempts [before surgical procedure]

    Number of laryngoscopy attempts before successful tracheal intubation

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • 18 years and older

  • All consecutive patients for scheduled or non-scheduled surgery with or without indication of rapid sequence induction (full-stomach)

  • Undergoing general anesthesia with orotracheal intubation

Exclusion Criteria:
  • Age < 18 years

  • Hemodynamic instability

  • Intubation without laryngoscopy (i.e., fiberoptic intubation for anticipated "cannot ventilate situation" or mouth opening < 2 cm), facial surgery

  • Adults subject to legal protection

  • Pregnancy (due to higher risk of oxygen desaturation and aspiration)

Contacts and Locations

Locations

Site City State Country Postal Code
1 Beth Israel Deaconess Medical Center Boston Massachusetts United States 02215

Sponsors and Collaborators

  • Beth Israel Deaconess Medical Center

Investigators

  • Principal Investigator: Daniel S Talmor, MD, Beth Israel Deaconess Medical Center

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Daniel Talmor, Anesthesia Department Chair, Beth Israel Deaconess Medical Center
ClinicalTrials.gov Identifier:
NCT05495841
Other Study ID Numbers:
  • 2022P000396
First Posted:
Aug 10, 2022
Last Update Posted:
Aug 10, 2022
Last Verified:
Aug 1, 2022
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No

Study Results

No Results Posted as of Aug 10, 2022