Vacuum-formed Retainer Versus Bonded Retainer to Prevent Relapse After Orthodontic Treatment
Study Details
Study Description
Brief Summary
The purpose of this trial is to evaluate and compare stability after orthodontic treatment with an Essix retainer and a bonded cuspid-to-cuspid retainer (CTC), respectively in the mandibular arch and longitudinally follow these patients over time up to 5 years. The patients' perceptions of the two methods are also evaluated with questionnaires during the follow-up period.
A further aim of this study is to analyze the relationship between diagnosis, treatment outcome, treatment time, age at start of treatment and stability with an Essix retainer in the maxilla.
The null hypotheses are:
-
that there is no difference in retention capacity between Essix retainer and cuspid-to-cuspid retainer
-
that there is no difference in patients' perception between Essix retainer and cuspid-to-cuspid retainer
-
that there is no difference in retention capacity for Essix retainer in the maxilla concerning diagnosis before treatment, treatment outcomes, treatment time and age at start of treatment
Condition or Disease | Intervention/Treatment | Phase |
---|---|---|
|
N/A |
Detailed Description
The study is conducted at the Orthodontic Clinic, Gävle, Sweden and consists of 104 patients. All patients are treated with fixed appliances in the upper and lower jaw (standard .022 straight wire), both with and without extractions. The patients are randomized into two groups with 52 patients in each group (Group A: cuspid-to-cuspid retainer, Group B: Essix retainer).
Dental cast are obtained at the debond appointment (T1) and at the follow-up controls after six months (T2), 18 months (T3) and 60 months (T4) for both groups.
At the visit two weeks in retention and at the follow-up visits after 6, 18 and 60 months the patients assess questionnaires in order to evaluate their experience of retention with the retention device.
Study Design
Arms and Interventions
Arm | Intervention/Treatment |
---|---|
Experimental: Group A: CTC retainer + Essix retainer The CTC is bonded directly after debonding. The Essix retainer maxilla is handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. |
Device: CTC retainer
The CTC retainer consists of 0.8 hard Remanium® wire (Dentaurum, Germany) and is bonded with Tetric Flow (Ivoclar Vivadent, Liechtenstein) to the lower canines directly after debonding.
Other Names:
Device: Essix retainer maxilla
The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances.
Other Names:
Procedure: Alginate impression
Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months.
Other: Questionnaire
A questionnaire is completed at the follow-up visits.
|
Active Comparator: Group B: Essix retainer + Essix retainer The Essix retainer maxilla and Essix retainer mandible are handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. |
Device: Essix retainer maxilla
The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances.
Other Names:
Device: Essix retainer mandible
The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances.
Other Names:
Procedure: Alginate impression
Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months.
Other: Questionnaire
A questionnaire is completed at the follow-up visits.
|
Outcome Measures
Primary Outcome Measures
- Changes in Tooth Position [Changes in tooth position (Little's Irregularity Index) were analysed 5 years (T4) after debonding (T1)]
Analyses of changes in tooth position on dental casts Little's Irregularity Index (in mm) 0=no crowding/irregularity, higher scores= more crowding/irregularity (worse outcome)
Secondary Outcome Measures
- Patients' Perception [T4 (5 years follow up)]
Analyses of patients' perception by validated self-report questionnaires to evaluate experiences of the retention techniques VAS (visual analog scale, 0-100) 0= low satisfaction 100= high satisfaction
Eligibility Criteria
Criteria
Inclusion Criteria:
- Patients treated with fixed appliances in both the maxilla and the mandible
Exclusion Criteria:
-
Rapid Maxillary Expansion (RME) for patients with severe transversal malocclusion
-
Treatment with segmented appliances
-
Patients with craniofacial anomalies and patients requiring orthognatic surgery
-
Patients with missing mandibular incisor
Contacts and Locations
Locations
No locations specified.Sponsors and Collaborators
- Region Gävleborg
- Umeå University
Investigators
- Principal Investigator: Anke Krämer, DDS, Folktandvården Gävleborg AB, Specialisttandvården ortdonti
Study Documents (Full-Text)
More Information
Publications
- Atack N, Harradine N, Sandy JR, Ireland AJ. Which way forward? Fixed or removable lower retainers. Angle Orthod. 2007 Nov;77(6):954-9.
- Bennett ME, Tulloch JF. Understanding orthodontic treatment satisfaction from the patients' perspective: a qualitative approach. Clin Orthod Res. 1999 May;2(2):53-61.
- Feldmann I, List T, Bondemark L. Orthodontic anchoring techniques and its influence on pain, discomfort, and jaw function--a randomized controlled trial. Eur J Orthod. 2012 Feb;34(1):102-8. doi: 10.1093/ejo/cjq171. Epub 2011 Feb 7.
- Feldmann I, List T, John MT, Bondemark L. Reliability of a questionnaire assessing experiences of adolescents in orthodontic treatment. Angle Orthod. 2007 Mar;77(2):311-7.
- Hichens L, Rowland H, Williams A, Hollinghurst S, Ewings P, Clark S, Ireland A, Sandy J. Cost-effectiveness and patient satisfaction: Hawley and vacuum-formed retainers. Eur J Orthod. 2007 Aug;29(4):372-8.
- Jäderberg S, Feldmann I, Engström C. Removable thermoplastic appliances as orthodontic retainers--a prospective study of different wear regimens. Eur J Orthod. 2012 Aug;34(4):475-9. doi: 10.1093/ejo/cjr040. Epub 2011 Apr 20.
- Kumar AG, Bansal A. Effectiveness and acceptability of Essix and Begg retainers: a prospective study. Aust Orthod J. 2011 May;27(1):52-6.
- Lindauer SJ, Shoff RC. Comparison of Essix and Hawley retainers. J Clin Orthod. 1998 Feb;32(2):95-7.
- Littlewood SJ, Millett DT, Doubleday B, Bearn DR, Worthington HV. Retention procedures for stabilising tooth position after treatment with orthodontic braces. Cochrane Database Syst Rev. 2016 Jan 29;(1):CD002283. doi: 10.1002/14651858.CD002283.pub4. Review.
- Reitan K. Clinical and histologic observations on tooth movement during and after orthodontic treatment. Am J Orthod. 1967 Oct;53(10):721-45.
- Renkema AM, Al-Assad S, Bronkhorst E, Weindel S, Katsaros C, Lisson JA. Effectiveness of lingual retainers bonded to the canines in preventing mandibular incisor relapse. Am J Orthod Dentofacial Orthop. 2008 Aug;134(2):179e1-8. doi: 10.1016/j.ajodo.2008.06.003.
- Rowland H, Hichens L, Williams A, Hills D, Killingback N, Ewings P, Clark S, Ireland AJ, Sandy JR. The effectiveness of Hawley and vacuum-formed retainers: a single-center randomized controlled trial. Am J Orthod Dentofacial Orthop. 2007 Dec;132(6):730-7.
- Sheridan JJ, LeDoux W, McMinn R. Essix retainers: fabrication and supervision for permanent retention. J Clin Orthod. 1993 Jan;27(1):37-45.
- Thickett E, Power S. A randomized clinical trial of thermoplastic retainer wear. Eur J Orthod. 2010 Feb;32(1):1-5. doi: 10.1093/ejo/cjp061. Epub 2009 Oct 14.
- Yu Y, Sun J, Lai W, Wu T, Koshy S, Shi Z. Interventions for managing relapse of the lower front teeth after orthodontic treatment. Cochrane Database Syst Rev. 2013 Sep 6;(9):CD008734. doi: 10.1002/14651858.CD008734.pub2. Review.
- CFUG-557411
Study Results
Participant Flow
Recruitment Details | |
---|---|
Pre-assignment Detail |
Arm/Group Title | Group A: CTC Retainer + Essix Retainer | Group B: Essix Retainer + Essix Retainer |
---|---|---|
Arm/Group Description | The CTC is bonded directly after debonding. The Essix retainer maxilla is handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. CTC retainer: The CTC retainer consists of 0.8 hard Remanium® wire (Dentaurum, Germany) and is bonded with Tetric Flow (Ivoclar Vivadent, Liechtenstein) to the lower canines directly after debonding. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits. | The Essix retainer maxilla and Essix retainer mandible are handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Essix retainer mandible: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits. |
Period Title: Overall Study | ||
STARTED | 52 | 52 |
COMPLETED | 39 | 35 |
NOT COMPLETED | 13 | 17 |
Baseline Characteristics
Arm/Group Title | Group A: CTC Retainer + Essix Retainer | Group B: Essix Retainer + Essix Retainer | Total |
---|---|---|---|
Arm/Group Description | The CTC is bonded directly after debonding. The Essix retainer maxilla is handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. CTC retainer: The CTC retainer consists of 0.8 hard Remanium® wire (Dentaurum, Germany) and is bonded with Tetric Flow (Ivoclar Vivadent, Liechtenstein) to the lower canines directly after debonding. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits. | The Essix retainer maxilla and Essix retainer mandible are handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Essix retainer mandible: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits. | Total of all reporting groups |
Overall Participants | 52 | 52 | 104 |
Age (years) [Mean (Standard Deviation) ] | |||
Mean (Standard Deviation) [years] |
17.1
(1.9)
|
17.1
(2.4)
|
17.1
(2.2)
|
Sex: Female, Male (Count of Participants) | |||
Female |
26
50%
|
26
50%
|
52
50%
|
Male |
26
50%
|
26
50%
|
52
50%
|
Ethnicity (NIH/OMB) (Count of Participants) | |||
Hispanic or Latino |
0
0%
|
0
0%
|
0
0%
|
Not Hispanic or Latino |
0
0%
|
0
0%
|
0
0%
|
Unknown or Not Reported |
52
100%
|
52
100%
|
104
100%
|
Region of Enrollment (participants) [Number] | |||
Sweden |
52
100%
|
52
100%
|
104
100%
|
Outcome Measures
Title | Changes in Tooth Position |
---|---|
Description | Analyses of changes in tooth position on dental casts Little's Irregularity Index (in mm) 0=no crowding/irregularity, higher scores= more crowding/irregularity (worse outcome) |
Time Frame | Changes in tooth position (Little's Irregularity Index) were analysed 5 years (T4) after debonding (T1) |
Outcome Measure Data
Analysis Population Description |
---|
Dental casts were analysed. As data were not normal distributed, median values are reported. |
Arm/Group Title | Group A: CTC Retainer + Essix Retainer | Group B: Essix Retainer + Essix Retainer |
---|---|---|
Arm/Group Description | The CTC is bonded directly after debonding. The Essix retainer maxilla is handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. CTC retainer: The CTC retainer consists of 0.8 hard Remanium® wire (Dentaurum, Germany) and is bonded with Tetric Flow (Ivoclar Vivadent, Liechtenstein) to the lower canines directly after debonding. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits. | The Essix retainer maxilla and Essix retainer mandible are handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Essix retainer mandible: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits. |
Measure Participants | 39 | 35 |
Median (Inter-Quartile Range) [millimeters] |
0.05
|
0.62
|
Statistical Analysis 1
Statistical Analysis Overview | Comparison Group Selection | Group A: CTC Retainer + Essix Retainer, Group B: Essix Retainer + Essix Retainer |
---|---|---|
Comments | ||
Type of Statistical Test | Other | |
Comments | GEE analysis | |
Statistical Test of Hypothesis | p-Value | 0.0002 |
Comments | ||
Method | GEE analysis | |
Comments | ||
Method of Estimation | Estimation Parameter | GEE analysis |
Estimated Value | 0.99 | |
Confidence Interval |
(2-Sided) 95% 0.48 to 1.51 |
|
Parameter Dispersion |
Type: Value: |
|
Estimation Comments |
Title | Patients' Perception |
---|---|
Description | Analyses of patients' perception by validated self-report questionnaires to evaluate experiences of the retention techniques VAS (visual analog scale, 0-100) 0= low satisfaction 100= high satisfaction |
Time Frame | T4 (5 years follow up) |
Outcome Measure Data
Analysis Population Description |
---|
Adolescent patients at debond (baseline), adults after 5 years |
Arm/Group Title | Group A: CTC Retainer + Essix Retainer | Group B: Essix Retainer + Essix Retainer |
---|---|---|
Arm/Group Description | The CTC is bonded directly after debonding. The Essix retainer maxilla is handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. CTC retainer: The CTC retainer consists of 0.8 hard Remanium® wire (Dentaurum, Germany) and is bonded with Tetric Flow (Ivoclar Vivadent, Liechtenstein) to the lower canines directly after debonding. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits. | The Essix retainer maxilla and Essix retainer mandible are handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Essix retainer mandible: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits. |
Measure Participants | 39 | 35 |
Median (Inter-Quartile Range) [score on a scale] |
93
|
92
|
Statistical Analysis 1
Statistical Analysis Overview | Comparison Group Selection | Group A: CTC Retainer + Essix Retainer, Group B: Essix Retainer + Essix Retainer |
---|---|---|
Comments | ||
Type of Statistical Test | Other | |
Comments | Mann-Whitney U test | |
Statistical Test of Hypothesis | p-Value | 0.55 |
Comments | ||
Method | Wilcoxon (Mann-Whitney) | |
Comments |
Adverse Events
Time Frame | Observation time: 5 years after debonding (T1-T4) | |||
---|---|---|---|---|
Adverse Event Reporting Description | ||||
Arm/Group Title | Group A: CTC Retainer + Essix Retainer | Group B: Essix Retainer + Essix Retainer | ||
Arm/Group Description | The CTC is bonded directly after debonding. The Essix retainer maxilla is handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. CTC retainer: The CTC retainer consists of 0.8 hard Remanium® wire (Dentaurum, Germany) and is bonded with Tetric Flow (Ivoclar Vivadent, Liechtenstein) to the lower canines directly after debonding. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits. | The Essix retainer maxilla and Essix retainer mandible are handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Essix retainer mandible: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits. | ||
All Cause Mortality |
||||
Group A: CTC Retainer + Essix Retainer | Group B: Essix Retainer + Essix Retainer | |||
Affected / at Risk (%) | # Events | Affected / at Risk (%) | # Events | |
Total | 0/52 (0%) | 0/52 (0%) | ||
Serious Adverse Events |
||||
Group A: CTC Retainer + Essix Retainer | Group B: Essix Retainer + Essix Retainer | |||
Affected / at Risk (%) | # Events | Affected / at Risk (%) | # Events | |
Total | 0/52 (0%) | 0/52 (0%) | ||
Other (Not Including Serious) Adverse Events |
||||
Group A: CTC Retainer + Essix Retainer | Group B: Essix Retainer + Essix Retainer | |||
Affected / at Risk (%) | # Events | Affected / at Risk (%) | # Events | |
Total | 0/52 (0%) | 0/52 (0%) |
Limitations/Caveats
More Information
Certain Agreements
Principal Investigators are NOT employed by the organization sponsoring the study.
There is NOT an agreement between Principal Investigators and the Sponsor (or its agents) that restricts the PI's rights to discuss or publish trial results after the trial is completed.
Results Point of Contact
Name/Title | Anke Krämer |
---|---|
Organization | Folktandvården Gävleborg AB |
Phone | +4625155680 |
anke.kramer@regiongavleborg.se |
- CFUG-557411