Pace-Conduct: Pacing to Maintain Physiologic Ventricular Activation

Sponsor
Klinikum-Fuerth (Other)
Overall Status
Recruiting
CT.gov ID
NCT04416958
Collaborator
University of Erlangen-Nürnberg (Other), University of Trieste (Other)
200
1
155
1.3

Study Details

Study Description

Brief Summary

Right ventricular pacing causes ventricular dyssynchrony and may be associated with impaired outcome. In the last decade, several approaches for more physiological pacing became available and were implemented in the latest guidelines. However, compared to conventional device implantation, cardiac resynchronization, His bundle pacing and left bundle area pacing remain demanding procedures in the individual case. Goal of the single center observational "Pace conduct" study is to evaluate implantation success, safety and outcome of pacing methods that maintain physiologic ventricular activation.

Condition or Disease Intervention/Treatment Phase
  • Device: cardiac implantable electronic device (CIED) implantation

Detailed Description

Background:

Conventional ectopic myocardial right ventricular pacing (RVP) causes ventricular dyssynchrony and may be associated with reverse ventricular remodeling, reduced ejection fraction (EF), left ventricular dilatation, functional mitral valve regurgitation, heart failure and an increased rate of new onset atrial fibrillation.

Dependent on individual patient's characteristics, several strategies are established to prevent and to overcome the potential drawbacks of chronic RVP. In general, unnecessary ectopic RVP should be avoided. For example, in patients with sinus node disease and intact atrioventricular (AV) conduction, atrial pacing, AV (search) hysteresis or AAI-DDD/ADI pacing may be used. In patients with impaired cardiac function and an expected higher percentage of RVP, pacing strategies for cardiac resynchronization are indicated. Conventional cardiac resynchronization therapy (CRT) uses an additional transvenous left ventricular lead for synchronous ventricular stimulation and was shown to shorten QRS duration and to reduce morbidity and mortality in patients with chronic heart failure, left bundle branch block (LBBB) and reduced EF. Due to the non-physiological left ventricular epicardial stimulation, however, conventional CRT is associated with 30% of non-responders and may even prolong ventricular activation in patients with narrower QRS complex. First described in 1968, His bundle pacing (HBP) has evolved to an increasingly used alternative for cardiac pacing. Currently, HBP is regarded the most physiologic approach for ventricular stimulation because it prevents ventricular dyssynchrony and its potential fatal long-term consequences by preserving normal electrical activation of the ventricles. Clinical benefit of HBP has been shown compared with conventional permanent RVP and CRT. Recent studies documented restoration of normal electrical and mechanical left ventricular synchrony for both selective and non-selective HBP. However, compared with conventional RVP the implantation procedure for HBP is much more demanding requiring exact placement of the pacing lead within the anatomically variable His bundle area. Alternatively, the correction of bundle branch conduction disorders has been demonstrated for left bundle branch area (LBBA) pacing. As a consequence, current guidelines recommend pacing methods that maintain physiologic ventricular activation in patients with atrioventricular block who have an indication for permanent pacing with a LVEF between 36% and 50% and are expected to require ventricular pacing more than 40% of the time (class IIa indication).

In summary, there is increasing evidence showing the benefits of the different strategies for physiologic pacing but the appropriate use of these approaches may be challenging in the individual case. Therefore, appropriate patient selection, implantation approaches, device programming and follow-up require further intensive evaluation.

Objective:

Main goal of the study is to evaluate implantation success for pacing methods aiming to maintain physiologic ventricular activation. Procedural success is defined as stable lead positioning and effective pacing within the target area with an appropriate and stable pacing threshold.

Secondary goals of the study are to document and to evaluate

  • procedural parameters (e.g. venous access, time needed for lead implant, procedural duration, radiation) and adverse events dependent on procedural approaches and patients characteristics,

  • performance of the implanted system (sensing, pacing thresholds) and clinical outcome during routine follow-up

Study design:

Single center, non-randomized, observational study, retrospective data analysis, on-going prospective patient enrollment, descriptive statistics.

Center: Klinikum Fuerth (Dept. for Heart and Lung diseases, section for clinical electrophysiology) / Germany in cooperation with the Dept. of Cardiology of the University Erlangen / Germany and the University of Trieste / Italy.

Patients and methods:

Primary endpoint: Implantation success. Effective pacing and acceptable pacing threshold at the targeted lead position. Target for lead placement is the area with maximum delayed ventricular activation for transvenous CRT, the His bundle for selective or non-selective HBP and the right interventricular septum with left bundle branch capture for LBBA pacing, respectively. Target thresholds for the lead placed within the coronary sinus or at the intrinsic conduction system is <2.5 V @ 1 ms with a maximum acceptable threshold of <4.0 V @ 2 ms or <5 V @ 1 ms. Target for all other leads is <1 V @ 0.5 ms.

Secondary endpoints: patient characteristics and association with outcome. Implantation success and outcome correlated with patient characteristics including electrocardiogram and echocardiographic parameter and procedure related techniques and parameter. Safety: radiation exposure, number and type of adverse events and adverse device related events. Follow-up: device function, interrogation, programming and clinical outcome as evaluated in routine follow-up, incl. ECG, echocardiography and parameter for assessment of heart failure. Subpopulations: managed ventricular pacing, His bundle pacing, LBB-area pacing, CRT. Implantation with or without electroanatomic mapping system.

Inclusion criteria:

Implantation of a pacemaker or ICD according to the current guidelines (Class I or IIa indication) aiming to avoid pacing induced dyssynchrony, e.g. managed ventricular pacing, His-bundle pacing, LBB-area pacing or conventional transvenous CRT. Age ≥ 18 years.

Exclusion criteria:

No given informed consent for the procedure. No follow up data available.

Sample size:

For the observational study, there is no pre-specified sample-size. Data from 200 patients and procedures are expected.

Data security:

Study related data are collected by the study investigators in an anonymous clinic-internal data-base that is password protected. All investigators have to provide valid GCP training.

Risk estimation:

The study is observational and descriptive with anonymized data collection and data analysis. Therefore, the study adds no risk to the study population.

Ethics:

The "Pace-Conduct" study has been approved by the responsible ethics committee of the Friedrich- Alexander University Erlangen, Germany (145_20 Bc)

Study Design

Study Type:
Observational [Patient Registry]
Anticipated Enrollment :
200 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
Pacing for Cardiac Resynchronisation Using the Intrinsic Conduction System to Maintain Physiologic Ventricular Activation
Actual Study Start Date :
Jan 1, 2018
Anticipated Primary Completion Date :
Dec 1, 2025
Anticipated Study Completion Date :
Dec 1, 2030

Arms and Interventions

Arm Intervention/Treatment
CIED for cardiac resynchronisation

Patients implanted with an CIED for cardiac resynchronisation aiming to avoid pacing induced ventricular dyssynchrony, e.g. His bundle pacing, LBB-area pacing, CRT. These different implanted types of devices may be further analysed as subgroups.

Device: cardiac implantable electronic device (CIED) implantation
CIED Implantation according to the Guidelines aiming to avoid pacing induced dyssynchrony

Outcome Measures

Primary Outcome Measures

  1. CIED Implantation success [peri-procedural]

    successful Pacemaker- or ICD implantation with effective pacing and acceptable pacing threshold in the targeted area

Secondary Outcome Measures

  1. pre-operative: Implantation related Patient characteristics [1 month post implantation]

    association with procedural and post-implant outcome

  2. intra-procedural: implant success related with procedural characteristics [peri-procedural]

    correlation of Implantation success with Patient characteristics and procedural technical Parameter, eg. use of an electroanatomic mapping system

  3. peri-procedural: safety and radiation [peri-procedural]

    Radiation exposure and number and type of all adverse Events and adverse device associated events

  4. follow-up: device function [one year]

    device parameter and programming during follow up

  5. follow-up: outcome [one year]

    clinical Outcome during follow up

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Pacemaker or ICD Implantation aiming to avoid pacing induced ventricular dyssynchrony according to current guidelines

  • age >= 18 years

Exclusion Criteria:
  • no informed consent for the procedure given

  • no follow-up data

Contacts and Locations

Locations

Site City State Country Postal Code
1 Klinikum Fuerth Fuerth Bavaria Germany 90766

Sponsors and Collaborators

  • Klinikum-Fuerth
  • University of Erlangen-Nürnberg
  • University of Trieste

Investigators

  • Principal Investigator: Dirk Bastian, MD, Klinikum-Fuerth

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Klinikum-Fuerth
ClinicalTrials.gov Identifier:
NCT04416958
Other Study ID Numbers:
  • Pace_Cond_KHF
First Posted:
Jun 4, 2020
Last Update Posted:
Dec 10, 2021
Last Verified:
Dec 1, 2021
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No