Benfit of Remote Monitoring in Pacemaker

Sponsor
Yonsei University (Other)
Overall Status
Recruiting
CT.gov ID
NCT06043570
Collaborator
(none)
900
1
2
58.4
15.4

Study Details

Study Description

Brief Summary

Modern CIEDs are equipped with remote monitoring (RM) technology, which provides automatic transmissions of diagnostics and technical data from the implanted devices to the attending physician. RM has been shown to be a safe alternative to the conventional in-hospital visits, especially for low-risk patients, such as pacemaker recipients. These regular office visits include examinations of device function and patient clinical status, and may prompt the reprogramming of the device or changes in medication regimens. The efficiency of this strategy is, however, questionable since, in the majority of scheduled visits, the device programming or drug regimen is left unchanged. To optimize the follow-up of device recipients, systems have been developed, which allow the automatic teletransmission of data stored in the devices' memories, including battery voltage, lead characteristics, and arrhythmias. The data sent by a home transmitter allow the remote surveillance of patients and eliminate unnecessary ambulatory visits. Clinical studies of these new systems have been conducted mostly in recipients of cardioverter defibrillators, and only a few studies of permanently paced patients have been published.

However, due to the absence of medical regulations and systems for remote monitoring in Korea, the government does not provide clear guidelines and the Korean HIRA (Health Insurance Review & Assessment Service) is yet to set any reimbursement standards for home-transmitter and remote monitoring. As a result, most Korean physicians cannot practically use remote monitoring for CIED patients. Therefore, this project shall contribute to address the benefits of remote monitoring to the government and expediate the system to be set in the country.

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in the general population. AF has enormous socioeconomic implications because it increases the risk of mortality and morbidity resulting from stroke, congestive heart failure, dementia and impaired quality of life. To prevent the AF-related complication, early detection of AF is very important. Despite the latest HRS Expert Consensus Statement which has set a class I recommendation for RM as useful tool for the early detection and quantification of AF, there are still few data on the clinical reactions triggered by the AHRE detected by RM of CIEDs and on their possible benefit on patient's outcome.

The incidence of atrial high rate episodes (AHRE)/subclinical AF in patients with a pacemaker/implanted device is 30-70%, but it may be lower in the general population. Longer episodes of AHRE/subclinical AF (minimum of 5-6 min) are associated with an increased risk of clinical AF, ischemic stroke, major adverse cardiovascular events, and cardiovascular death.13 Clinical AF will reportedly develop in 1 in 5-6 of patients within 2.5 years after diagnosing AHRE/subclinical AF.

The remote monitoring feature is available in all geographies while it is yet to be reimbursed in South Korea. To be reimbursed by the NHIS of Korea, the data supporting the benefit of RM is necessary. By comparing clinical and economic benefits of remote monitoring, we might be able to set a guideline on the usage of remote monitoring in pacemaker patients.

Condition or Disease Intervention/Treatment Phase
  • Device: Remote Monitoring arm
N/A

Detailed Description

  • Study Objective Primary study objective The primary objective of this non-inferiority, prospective trial in Korean population is to confirm that the proportion of patients who experienced at least one major adverse event (MAE), including (i) death, (ii) hospitalization for complications related to the pacing system, and (iii) hospitalization for an adverse cardiovascular event, is not higher in the remote follow-up (active) than in the standard care (control) group.

  • Secondary objectives The secondary objectives of the trial are to address the economic benefits of remote monitoring to the government and expediate the system to be set in the country. Through this trial, we expect to set reimbursement policy in corporation with KHRS (Korean Heart Rhythm Society) including home transmitter. In addition, since Korea has one of the highest usage rate of smartphones even in elderly groups compared to Europe or North America, we are to suggest a set of guidelines for patient care and follow up schedules for remote monitoring patients according to Korean culture and circumstances.

  • Study Design We propose to prospectively recruit 900 patients with pacemaker with SenseAbility feature implantation in multiple sites in Korea.

  • Eligible patients should be enrolled in remote monitoring system 0 to 45 days after successful device implantation and then randomly assigned in a 1:1 ratio to the RM or conventional follow-up group.

  • In the RM follow-up arm, the patients are not mandated to visit the clinic unless there is unscheduled call due to adverse event notification.

  • In the conventional follow-up arm, the patients should be seen at the clinic according to each center's custom but no longer than 1 year between each visit. Follow-up should be continued accordingly until two-years of device implant.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
900 participants
Allocation:
Randomized
Intervention Model:
Parallel Assignment
Masking:
None (Open Label)
Primary Purpose:
Prevention
Official Title:
Evaluation of Clinical and Economic Benefit Using Remote Monitoring in Patients With Pacemaker (REMOTE-PM)
Actual Study Start Date :
Jan 17, 2023
Anticipated Primary Completion Date :
Oct 1, 2025
Anticipated Study Completion Date :
Dec 1, 2027

Arms and Interventions

Arm Intervention/Treatment
Experimental: Remote Monitoring follow up

Device: Remote Monitoring arm
Patients will be follow-up using remote monitoring. In the RM follow-up arm, the patients are not mandated to visit the clinic unless there is unscheduled call due to adverse event notification.

No Intervention: Conventional Follow up

Outcome Measures

Primary Outcome Measures

  1. major adverse event (MAE) [Arm 1: 6 month, 12 month, 18 month, 24 month, anytime using remote monitoring - Arm 2: 6 month, 12 month, 18 month, 24 month]

    major adverse event (MAE), including all-cause death and hospitalizations for device-related or cardiovascular adverse events

Secondary Outcome Measures

  1. Economic benefit by remote mononitoring [24 month]

    economic benefit of each treatment

  2. all-cause death [Arm 1: 6 month, 12 month, 18 month, 24 month, anytime using remote monitoring - Arm 2: 6 month, 12 month, 18 month, 24 month]

  3. hospitalizations for device-related events [Arm 1: 6 month, 12 month, 18 month, 24 month, anytime using remote monitoring - Arm 2: 6 month, 12 month, 18 month, 24 month]

  4. cardiovascular adverse events [Arm 1: 6 month, 12 month, 18 month, 24 month, anytime using remote monitoring - Arm 2: 6 month, 12 month, 18 month, 24 month]

  5. AHRE/subclinical AF [Arm 1: 6 month, 12 month, 18 month, 24 month, anytime using remote monitoring - Arm 2: 6 month, 12 month, 18 month, 24 month]

  6. clinical AF [Arm 1: 6 month, 12 month, 18 month, 24 month, anytime using remote monitoring - Arm 2: 6 month, 12 month, 18 month, 24 month]

  7. time to change of management including OAC [Arm 1: 6 month, 12 month, 18 month, 24 month, anytime using remote monitoring - Arm 2: 6 month, 12 month, 18 month, 24 month]

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 80 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Age: 18-80 years

  • Patients with permanent pacemaker with SenseAbility feature & RM

  • Ability to provide informed consent and to complete the study and required follow-up ④ Those who refuse to use remote monitoring system or who live in an environment where remote monitoring system cannot be utilized.

  • Patient who refuse to use or expected to use less than 75% of remote monitoring system.

Exclusion Criteria:
  • Severe hepatic and renal insufficiency (AST or ALT ≥ three times of normal upper limit; SCr > 3.5 mg/dl or Ccr < 30ml/min)

  • Thyroid gland dysfunction

  • Pregnancy ④ Malignant tumor

  • Severe organic heart disease (such as moderate to severe mitral regurgitation, dilated cardiomyopathy, hypertrophic cardiomyopathy, severe heart valve disease)

  • Life expectancy < 12 months ⑦ Patients unable or unwilling to cooperate in the study procedures.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Severance Cardiovascular Hospital Yonsei University Seoul Korea, Republic of

Sponsors and Collaborators

  • Yonsei University

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Yonsei University
ClinicalTrials.gov Identifier:
NCT06043570
Other Study ID Numbers:
  • 1-2022-0049
First Posted:
Sep 21, 2023
Last Update Posted:
Sep 21, 2023
Last Verified:
Sep 1, 2023
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by Yonsei University

Study Results

No Results Posted as of Sep 21, 2023