Purpose: It is one of the important nursing interventions for patients in intensive care units with strict glycemic protocol to determine whether glucose values are different for a bedside glucose meter compared to the main clinical laboratory and whether the blood sampling site has a significant effect on glucose values. In this study, it is aimed to compare whether there is a difference between blood samples from venous, arterial, capillary and thumb base region, which is defined as an alternative region to the fingertip, in blood glucose level measurement, and to compare the consistency between the thumb base region and fingertip region and pain and results of the different methods used.

Methods: The universe of the research consists of Bursa Uludağ University Health Practice and Patients will be hospitalized in the General Surgery Intensive Care Unit of the Research Center between April and September 2023. 125 patients who meet the sample selection criteria will form the sample of the study. The sample size of the study was determined statistically with the GPower (3.1.7) program. Comparison of blood glucose measurement taken with different methods in the power analysis to determine the sample size. When the effect size of blood glucose was determined as 0.9, it was calculated that a total of 125 patients should be included for a significance level of 0.05 and a power of 80%. Research '' Ergin E., Zaybak A. (2022). Effects of different methods used to take blood samples on blood glucose measurements. Reference is made to Clinical Nursing Research, 31(1), (p.29-38).DOI: 10.1177/10547738211024782". 125 patients who meet the sample selection criteria will form the sample of the study. The sample size of the study was determined statistically with the GPower (3.1.7) program. When the effect size of blood glucose was determined as 0.9 in the comparison of blood glucose measurement taken with different methods in the power analysis performed to determine the sample size, it was calculated that a total of 125 patients should be included for a significance level of 0.05 and a power of 80%.

Condition or Disease Intervention/Treatment Phase
  • Other: Blood Glucose Measurement Values Taken by Different Methods
N/A

Detailed Description

Purpose: In this study, it is aimed to compare whether there is a difference between blood samples from venous, arterial, capillary, and thumb base regions, which is defined as an alternative region to the fingertip, in blood glucose level measurement, and to compare the consistency between the thumb base region and fingertip region and pain and results of the different methods used.

Design: This is a quasi-experimental study with a single group and simultaneous (matched) sample will conduct to determine whether glucose values are different for a bedside glucose meter compared to the main clinical laboratory and whether the blood sampling site has a significant effect on glucose values.

A central venous catheter blood sample will be taken from the patient by the guideline recommendations and placed in the biochemistry tube and taken to the laboratory by the researchers. This result is studied by the "biochemistry-glucose test" laboratory.

A capillary blood sample (right/left fingertip; thumb base) from the same patient will be evaluated with a glucometer (Accu-check).

Finally, from the same patient, the transducer set to which the arterial catheterization is connected will first be washed with 5 ccs 1% heparin, and blood glucose will be measured by taking a blood sample from the catheter. Then, it will be washed with 10 ccs 1% heparin and a blood sample will be taken from the catheter and blood glucose measurement will be made. An arterial blood sample (right/left fingertip; thumb base) from the same patient will be evaluated with a glucometer (Accu-check).

The purpose of examining this difference is whether a routine transduce set washing has an effect on blood glucose measurement in blood samples taken from patients with arterial catheterization. In total, blood samples will be collected from 3 different sites (central venous catheter, capillary, and arterial catheterization) in the same patient. In total, with 5 different techniques from 3 different regions of the same patient;

ARTERIAL BLOOD SAMPLE i) Washing with 5 ccs 1% Heparin fluid ii) Washing with 10 ccs 1% Heparin fluid CAPILAR BLOOD SAMPLE iii) Right / Left Fingertip iv) Thumb base CENTRAL VENOUS CATHETERIZATION BLOOD SAMPLE will be collected.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
125 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Intervention Model Description:
This is a quasi-experimental study with a single group and simultaneous (matched) sample will conduct with the purpose of to determine whether glucose values are different for a bedside glucose meter compared to the main clinical laboratory and whether the blood sampling site has a significant effect on glucose values.This is a quasi-experimental study with a single group and simultaneous (matched) sample will conduct with the purpose of to determine whether glucose values are different for a bedside glucose meter compared to the main clinical laboratory and whether the blood sampling site has a significant effect on glucose values.
Masking:
None (Open Label)
Masking Description:
single group sample, there is no blinding as everyone will be treated equally
Primary Purpose:
Supportive Care
Official Title:
Comparison of Blood Glucose Measurement Values Taken by Different Methods in Intensive Care Unit (ICU) Patients
Anticipated Study Start Date :
May 17, 2023
Anticipated Primary Completion Date :
Aug 31, 2024
Anticipated Study Completion Date :
Aug 31, 2024

Arms and Interventions

Arm Intervention/Treatment
Other: SINGLE GROUP

This is a quasi-experimental study with a single group and simultaneous (matched) sample will conduct with the purpose of to determine whether glucose values are different for a bedside glucose meter compared to the main clinical laboratory and whether the blood sampling site has a significant effect on glucose values.

Other: Blood Glucose Measurement Values Taken by Different Methods
In total, blood samples will be collected from 3 different sites (central venous catheter, capillary, arterial catheterization) in the same patient. In total, with 5 different techniques from 3 different regions from the same patient; ARTERIAL BLOOD SAMPLE i) Washing with 5 cc 1% Heparin fluid ii) Washing with 10 cc 1% Heparin fluid CAPILAR BLOOD SAMPLE iii) Right / Left Fingertip iv) Thumb base CENTRAL VENOUS CATHETERIZATION BLOOD SAMPLE will be collected.

Outcome Measures

Primary Outcome Measures

  1. Blood Glucose Measurement [baseline]

    In this comparison, the central venous catheter blood glucose measurement value will be taken as a baseline.

Secondary Outcome Measures

  1. Behavioral Pain Scale [through study completion, an average of 1 year]

    The behavioral pain scale consists of three main variables including facial expression, upper extremity, and compliance with the ventilator. An increase in the obtained score indicates an increase in the level of pain. The first items in each sub-dimension describe the absence of pain, the second items describe mild, the third items moderate, and the fourth items describe increased pain levels. Each sub-dimension is scored between 1 (no response to pain) and 4 (complete response to pain). The lowest score obtained from the scale is 3 and the highest score is 12. As the score increases, the level of pain increases. The first items indicate no pain, the second items indicate mild pain, the third items indicate the presence of moderate pain, and the fourth items indicate the presence of severe pain. The behavioral pain scale has been proven to be valid and reliable for assessing pain in intubated patients in the ICU.

  2. Visual Analog Scale [through study completion, an average of 1 year]

    It is a one-dimensional scale used in the measurement of VAS pain. Among the one-dimensional scales used to determine the severity of pain in patients, it was determined that the VAS measures more sensitively and is more reliable. The scale consists of a 100 mm long horizontal line. On one end are the phrases "No Pain" and on the other end "Unbearable Pain" describing the most severe pain possible. The patient is asked to mark his pain on the scale. The length of the line from the starting point of the scale to the point marked by the patient is measured and recorded in mm. After capillary blood glucose measurement is made, the patients will be educated by the researcher about the use of VAS before the research and the patients will be asked to evaluate their pain using VAS. It will be recorded in the data collection form as the numerical value obtained by measuring the point where the patient marked on the scale.

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • patients who age bigger than18

  • patients who have capillary fullness is good

  • patients who have a central venous catheter

  • patients who have an arterial catheter

Exclusion Criteria:
  • patients who have predibatic will be excluded from the study. The research has been added to the exclusion criteria and has been changed both in the relevant field in the system and in the project application file. In the ADA (American Diabetes Association) definition of prediabetes, IGT (Impaired Glucose Tolerance) (140-200 mg/dl), lower IAG (Impaired Fasting Glucose) (100-125 mg/dl) and additional supplementation according to
WHO (World Health Organization) It is based on the criteria of hemoglobin A1c (HbA1c:

Hemoglobin A1c) between 5.7% and 6.4% (ADA,2014). Meeting one of the three criteria is defined as prediabetes. Prediabetes screening is performed using 75 g OGTT, HbA1C, FPG, or a 2-hour oral glucose challenge test.

  • patients with Diabetes Mellitus,

  • patients with coagulopathy

  • patients who receive high-dose vasopressors, acetamifon, ascorbic acid, mannitol, corticosteroid, renal replacement therapy

  • patients who do not agree to participate in the research,

  • patients who have upper extremity amputation, cast, etc. (capillary blood sample cannot be taken for reasons)

Contacts and Locations

Locations

No locations specified.

Sponsors and Collaborators

  • Uludag University

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

Responsible Party:
Hulya Yilmaz, Pirincipal Investigator, PhD, Msc, Uludag University
ClinicalTrials.gov Identifier:
NCT05848362
Other Study ID Numbers:
  • 16/03/2022 - 6/10
First Posted:
May 8, 2023
Last Update Posted:
May 8, 2023
Last Verified:
May 1, 2023
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by Hulya Yilmaz, Pirincipal Investigator, PhD, Msc, Uludag University
Additional relevant MeSH terms:

Study Results

No Results Posted as of May 8, 2023