OCTTT: Overcoming Analgesic Tolerance to TENS

Sponsor
Kathleen Sluka (Other)
Overall Status
Completed
CT.gov ID
NCT03475082
Collaborator
(none)
40
5
102

Study Details

Study Description

Brief Summary

The purpose of this study is to determine if changing the frequency or intensity of transcutaneous electrical nerve stimulation (TENS) can reduce the development of tolerance to TENS treatment.

Condition or Disease Intervention/Treatment Phase
  • Device: Transcutaneous Electrical Nerve Stimulation
N/A

Detailed Description

Healthy adults will come daily for 5 consecutive days to the testing room. Pressure pain thresholds (PPT) will be the outcome measure and will be used to measure the subject's pain threshold to deep mechanical pressure. Subjects will push a button to stop the PPT test when they first begin to feel a sensation of pain. The PPT test will be done before TENS application. The TENS unit will be applied based on random assignment to 1 of 5 treatment types and subjects will not be told which group they are assigned to. Those groups are: 1) placebo TENS, 2) high frequency TENS, 3) alternating frequency TENS, 4) modulated frequency TENS, or 5) high frequency TENS with increased intensity daily. The TENS unit will be applied for 30 minutes. After 20 minutes the PPT test will be completed a second time. This procedure will occur on all 5 consecutive days of testing. Data will be measured and recorded by an assessor blind to subject group. Blinding will be assessed at the end of testing on day 5.

Study Design

Study Type:
Interventional
Actual Enrollment :
40 participants
Allocation:
Randomized
Intervention Model:
Parallel Assignment
Intervention Model Description:
Randomized controlled trial -double blindRandomized controlled trial -double blind
Masking:
Double (Participant, Outcomes Assessor)
Primary Purpose:
Treatment
Official Title:
Use of Modulating Frequency or Increasing Intensity to Overcome Analgesic Tolerance to Transcutaneous Electrical Nerve Stimulation (TENS) in Healthy Adults
Actual Study Start Date :
Jul 1, 2012
Actual Primary Completion Date :
Dec 1, 2019
Actual Study Completion Date :
Jan 1, 2021

Arms and Interventions

Arm Intervention/Treatment
Placebo Comparator: Placebo TENS

30 minute TENS treatment where the stimulation ramps slowly to zero after 45 seconds. The lights/display on the unit are identical to the Active unit.

Device: Transcutaneous Electrical Nerve Stimulation
Transcutaneous electrical nerve stimulation (TENS) is utilized clinically by a variety of health care professionals for the reduction of pain. The mechanisms by which TENS produces analgesia or reduces pain are only recently being elucidated. TENS is a non-invasive modality that is inexpensive, safe and easy to use with relatively few contraindications. Frequency of stimulation is broadly classified as high frequency (>50Hz), low frequency (<10Hz) TENS. Intensity is determined by the response of the patient as either sensory level (low-intensity) TENS strong but comfortable. With sensory level TENS, the voltage (i.e. amplitude) is increased only until the patient feels a comfortable tingling (perceived with high frequency) or tapping (perceived with low frequency) sensation without motor contraction. With strong but comfortable TENS the intensity is increased to a strong but comfortable level which may include muscle contraction.
Other Names:
  • TENS
  • Electrical stimulation
  • Active Comparator: High Frequency TENS

    30 minute TENS treatment at 100 Hertz (HZ). Intensity set at a strong but comfortable setting and subject asked to increase intensity as tolerated every 5 minutes. Final stimulation intensity at end of Day 1 treatment used for the remainder of the treatment sessions for all 5 days.

    Device: Transcutaneous Electrical Nerve Stimulation
    Transcutaneous electrical nerve stimulation (TENS) is utilized clinically by a variety of health care professionals for the reduction of pain. The mechanisms by which TENS produces analgesia or reduces pain are only recently being elucidated. TENS is a non-invasive modality that is inexpensive, safe and easy to use with relatively few contraindications. Frequency of stimulation is broadly classified as high frequency (>50Hz), low frequency (<10Hz) TENS. Intensity is determined by the response of the patient as either sensory level (low-intensity) TENS strong but comfortable. With sensory level TENS, the voltage (i.e. amplitude) is increased only until the patient feels a comfortable tingling (perceived with high frequency) or tapping (perceived with low frequency) sensation without motor contraction. With strong but comfortable TENS the intensity is increased to a strong but comfortable level which may include muscle contraction.
    Other Names:
  • TENS
  • Electrical stimulation
  • Active Comparator: Alternating frequency TENS

    30 minute TENS treatment with a pre programed mode alternating from 4 Hz and 100 HZ. Intensity set at a strong but comfortable setting and subject asked to increase intensity as tolerated every 5 minutes. Final stimulation intensity at end of Day 1 treatment used for the remainder of the treatment sessions for all 5 days.

    Device: Transcutaneous Electrical Nerve Stimulation
    Transcutaneous electrical nerve stimulation (TENS) is utilized clinically by a variety of health care professionals for the reduction of pain. The mechanisms by which TENS produces analgesia or reduces pain are only recently being elucidated. TENS is a non-invasive modality that is inexpensive, safe and easy to use with relatively few contraindications. Frequency of stimulation is broadly classified as high frequency (>50Hz), low frequency (<10Hz) TENS. Intensity is determined by the response of the patient as either sensory level (low-intensity) TENS strong but comfortable. With sensory level TENS, the voltage (i.e. amplitude) is increased only until the patient feels a comfortable tingling (perceived with high frequency) or tapping (perceived with low frequency) sensation without motor contraction. With strong but comfortable TENS the intensity is increased to a strong but comfortable level which may include muscle contraction.
    Other Names:
  • TENS
  • Electrical stimulation
  • Active Comparator: Modulated frequency TENS

    30 minute TENS treatment at a pre programmed mode that ramps between 4 and 125 HZ over 12 seconds. Intensity set at a strong but comfortable setting and subject asked to increase intensity as tolerated every 5 minutes. Final stimulation intensity at end of Day 1 treatment used for the remainder of the treatment sessions for all 5 days.

    Device: Transcutaneous Electrical Nerve Stimulation
    Transcutaneous electrical nerve stimulation (TENS) is utilized clinically by a variety of health care professionals for the reduction of pain. The mechanisms by which TENS produces analgesia or reduces pain are only recently being elucidated. TENS is a non-invasive modality that is inexpensive, safe and easy to use with relatively few contraindications. Frequency of stimulation is broadly classified as high frequency (>50Hz), low frequency (<10Hz) TENS. Intensity is determined by the response of the patient as either sensory level (low-intensity) TENS strong but comfortable. With sensory level TENS, the voltage (i.e. amplitude) is increased only until the patient feels a comfortable tingling (perceived with high frequency) or tapping (perceived with low frequency) sensation without motor contraction. With strong but comfortable TENS the intensity is increased to a strong but comfortable level which may include muscle contraction.
    Other Names:
  • TENS
  • Electrical stimulation
  • Active Comparator: High frequency TENS - increasing intensity

    30 minute TENS treatment at 100 HZ. Intensity set at initial strong but comfortable setting on day one as above, then subjects asked for possible increases in intensity every 5 minutes on all five days.

    Device: Transcutaneous Electrical Nerve Stimulation
    Transcutaneous electrical nerve stimulation (TENS) is utilized clinically by a variety of health care professionals for the reduction of pain. The mechanisms by which TENS produces analgesia or reduces pain are only recently being elucidated. TENS is a non-invasive modality that is inexpensive, safe and easy to use with relatively few contraindications. Frequency of stimulation is broadly classified as high frequency (>50Hz), low frequency (<10Hz) TENS. Intensity is determined by the response of the patient as either sensory level (low-intensity) TENS strong but comfortable. With sensory level TENS, the voltage (i.e. amplitude) is increased only until the patient feels a comfortable tingling (perceived with high frequency) or tapping (perceived with low frequency) sensation without motor contraction. With strong but comfortable TENS the intensity is increased to a strong but comfortable level which may include muscle contraction.
    Other Names:
  • TENS
  • Electrical stimulation
  • Outcome Measures

    Primary Outcome Measures

    1. Pressure Pain Threshold [Pre TENS and post TENS at initial (day 1) and final (day 5) study visit]

      Pressure pain thresholds (PPTs) change score measured in kilopascal (kPa) will be assessed on the forearm using a pressure algometer. The pressure algometer is mechanical pressure applied by the research assistant at a gradual rate by pushing the device against the skin. The device has a 1 cm2 pad that is in contact with the skin. The subject has a button that they push when the pressure first becomes painful (threshold)which stops the test and the pressure amount is recorded by the research assistant. This is the amount of pressured in kPa that is required to cause a subjective pain of 1/10 on a scale of 0 (no Pain) to 10 (Maximum Pain) rating by the subject. The change score from day 1 to Day 5 is the primary outcome measure.

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years to 65 Years
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    Yes
    Inclusion Criteria:
    • 18-65 Years of Age (YOA)

    • no current pain condition

    Exclusion Criteria:
    • Pregnancy

    • Cardiac pacemaker

    • Currently experiencing pain

    • Abnormal sensation in dominant forearm

    • History of seizures

    • Prior TENS use

    Contacts and Locations

    Locations

    No locations specified.

    Sponsors and Collaborators

    • Kathleen Sluka

    Investigators

    • Principal Investigator: Kathleen A Sluka, PhD, University of Iowa

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    Responsible Party:
    Kathleen Sluka, PT, PhD, University of Iowa
    ClinicalTrials.gov Identifier:
    NCT03475082
    Other Study ID Numbers:
    • 201203735
    First Posted:
    Mar 23, 2018
    Last Update Posted:
    Apr 29, 2021
    Last Verified:
    Apr 1, 2021
    Individual Participant Data (IPD) Sharing Statement:
    No
    Plan to Share IPD:
    No
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Product Manufactured in and Exported from the U.S.:
    No

    Study Results

    No Results Posted as of Apr 29, 2021