Study Description

Brief Summary

Sponsor is conducting this post market clinical study to evaluate the safety and effectiveness of its PROFEMUR® Preserve Classic Femoral Stem. This type of study is required by regulatory authorities for all devices that have been approved in Europe (EU) to evaluate the medium and long-term clinical evidence. This study has been designed in accordance with MEDDEV2.12/2 (European Medical Device Vigilance System) rev2 and ISO (International Organization of Standardization) 14155:2011 guidelines.

Condition or Disease Intervention/Treatment Phase
  • Device: PROFEMUR® Preserve Classic Femoral Stem

Study Design

Study Type:
Observational
Actual Enrollment :
0 participants
Observational Model:
Cohort
Time Perspective:
Other
Official Title:
Post Market Clinical Follow-Up Study for MicroPort PROFEMUR® Preserve Classic Femoral Stem
Anticipated Study Start Date :
Dec 1, 2021
Anticipated Primary Completion Date :
Dec 1, 2033
Anticipated Study Completion Date :
Dec 1, 2033

Outcome Measures

Primary Outcome Measures

  1. Component Survivorship [10 years post-operative]

    To estimate component survivorship of the PROFEMUR® Preserve Classic Femoral Stem at 1, 3, 5, 7, 10 years.

Secondary Outcome Measures

  1. HOOS Functional Scores [10 years post-operative]

    Complete characterization (mean, minimum, maximum, standard deviation) of functional scores as assessed by the Hip Disability and Osteoarthritis Outcome Score (HOOS), which ranges from 0 to 100 with a score of 0 indicating worst hip symptoms and 100 indicating no hip symptoms.

  2. EQ-5D-5L Functional Scores [10 years post-operative]

    Complete characterization (mean, minimum, maximum, standard deviation) of functional scores as assessed by EQ-5D-5L. This functional score data will be summarized over 5 domains, namely, mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each domain has 5 levels: no problems, slight problem, moderate problem, severe problem, inability to perform the activity. With no problems being the best outcome and inability to perform the activity being worst outcome.

  3. Subject Satisfaction as assessed by Forgotten Joint Score [10 years post-operative]

    To determine proportion of subjects being satisfied and level of their satisfaction as assessed by the Forgotten Joint Score (FJS). The study will be reporting forgotten joint score measures for the assessment of joint-specific patient reported outcomes. The questions focus on the patients' awareness of the implanted joint in everyday life or any unintended perception of a joint.

  4. Subject Satisfaction as assessed by Satisfaction Survey [10 years post-operative]

    To determine proportion of subjects being satisfied and level of their satisfaction as assessed by the Satisfaction Survey, consisting of questions asked about how satisfied the patient is with the new implant.

  5. Radiolucencies [10 years post-operative]

    To assess the presence of radiolucencies surrounding implanted components

  6. To assess subject safety [10 years post-operative]

    To assess safety of the PROFEMUR® Preserve Classic Femoral Stem through device-related adverse event findings and/or adverse device effects during follow-up visits.

  7. To assess device tolerability within subject [10 years post-operative]

    To assess tolerability of the PROFEMUR® Preserve Classic Femoral Stem through device-related adverse event findings and/or adverse device effects during follow-up visits.

Eligibility Criteria

Criteria

Ages Eligible for Study:
21 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  1. Has previously undergone or currently has been determined to undergo a primary THA with the study component MPO PROFEMUR® Preserve Classic Stem combined with any type of polyethylene or ceramic acetabular shells, acetabular liners and femoral heads.

  2. Has previously undergone or currently has been determined to undergo a primary THA for any of the following:

  • non-inflammatory degenerative joint disease such as osteoarthritis, avascular necrosis, ankylosis, protrusio acetabuli, and painful hip dysplasia;

  • inflammatory degenerative joint disease such as rheumatoid arthritis;

  • correction of functional deformity

  1. Willing and able to complete required study visits and assessments through the 10 year postoperative follow-up visit.

  2. Previously implanted subjects must be enrolled within 3 years (+ 6 months) of their primary THA implantation.

Exclusion Criteria:
  1. Skeletally immature (less than 21 years of age) at time of implantation

  2. Has or had an overt infection at the time of implantation

  3. Has or had a distant foci of infections (which may cause hematogenous spread to the implant site) at the time of implantation

  4. Has or had a rapid disease progression as manifested by joint destruction or bone absorption apparent on roentgenogram at the time of implantation

  5. Has or had inadequate neuromuscular status (e.g., prior paralysis, fusion, and/or inadequate abductor strength), poor bone stock, poor skin coverage around the joint which would make the procedure unjustifiable

  6. Has or had neuropathic joints

  7. Has or had hepatitis or HIV infection

  8. Has or had a neurological or musculoskeletal disease that may adversely affect gait or weight-bearing

  9. Has or had a revision procedure(s) where other treatments or devices have failed; and treatment of fractures that are unmanageable using other techniques

  10. Currently enrolled in another clinical investigation which could affect the endpoints of this protocol

  11. Has or had documented substance abuse issues

  12. Has an emotional or neurological condition that would pre-empt their ability or willingness to participate in the study

  13. Currently incarcerated or has impending incarceration

  14. Has a medical condition, as judged by the Investigator, that would interfere with the subject's ability to comply with the requirements of the protocol

Contacts and Locations

Locations

No locations specified.

Sponsors and Collaborators

  • MicroPort Orthopedics Inc.

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
MicroPort Orthopedics Inc.
ClinicalTrials.gov Identifier:
NCT04615039
Other Study ID Numbers:
  • 19H001C
First Posted:
Nov 4, 2020
Last Update Posted:
Dec 27, 2021
Last Verified:
Dec 1, 2021
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Dec 27, 2021