Predicting Blood Pressure in Patients Following Defibrillation

Sponsor
University of Utah (Other)
Overall Status
Completed
CT.gov ID
NCT02686307
Collaborator
(none)
33
36

Study Details

Study Description

Brief Summary

During tachyarrhythmias, central venous pressures increases while arterial blood pressure (BP) decreases. The result is mixed messages to the central nervous system. On one hand, the unloading of the arterial baroreceptors results in reflex tachycardia and an increase in sympathetic nerve activity (SNA). On the other hand, the increase in filling pressure and thus the activation of the cardiopulmonary baroreceptors result in reflex bradycardia and sympathoinhibition. The investigators have previously shown that during supraventricular and ventricular tachycardia, arterial baroreflex gain (BRG) predominates with minimal contribution from the cardiopulmonary BRG. In addition, the investigators found that arterial BRG directly correlates with BP recovery following tachycardia termination. The roles of the arterial and cardiopulmonary BRGs during ventricular fibrillation (VF) however, remain unknown. Furthermore, the role of the arterial BRG in determining 1) BP recovery following VF induction and 2) the frequency of ventricular tachycardia (VT)/VF events in patients undergoing implantation of an implantable cardioverter/defibrillator (ICD) remain unknown. Analysis of the changes in sinus node cycle length during VF inductions in patients undergoing the implantation of a dual chamber or triple chamber ICD, provide a unique opportunity at looking at the autonomic changes that accompany VF.

Condition or Disease Intervention/Treatment Phase
  • Procedure: ICD Implant

Detailed Description

Design: This is a prospective, non-randomized study. The purpose of the present study is 1) to assess whether the changes in sinus node cycle length during VF induction following ICD implant correlate with arterial BRG, and 2) to determine whether these changes, and thus arterial BRG, predict BP recovery post-defibrillation.

POSSIBLE BENEFITS: There are no specific potential benefits for subjects participating in this study. Results from this study should greatly improve investigator's knowledge of VF and BP control.

POSSIBLE RISKS & DISCOMFORTS: The potential risks or discomforts are associated with the assessment of arterial baroreflex gain.

Nitroprusside (NTP) infusion may result in significant drop in blood pressure, heart attack, rhythm disturbances and stroke. The risks associated with phenylephrine (PE) infusion include blood pressure elevation, heart attack, rhythm disturbances and stroke. The likelihood of this is very small since the medications will be given in small, gradual doses with close monitoring by study personnel and physicians. If significant blood pressure changes occur, the medication will be stopped immediately. Stopping the medication will quickly reverse any blood pressure changes since the drugs have a very short half-life.

Study procedures: Arterial baroreflex gain measurements will be performed either at the patient's bedside or in the electrophysiology laboratory as described below. BP will be monitored using a non-invasive arterial tonometer (Colin, San Antonio, TX) if performed at bedside, or a preexisting arterial line if performed in the laboratory. Logistical considerations, such as timing, would be a reason for performing the assessment at the bedside. The majority of the studies will be performed in the laboratory. This procedure will take approximately 20 minutes.

NTP will be injected into a peripheral vein as bolus infusion starting with 50mcg and increasing in 50mcg increments. NTP administration will be stopped when a 20-30mmHg drop in systolic or diastolic blood pressure is elicited. This will be followed by PE administration as a bolus infusion starting with 50mcg and increasing in 50mcg increments. PE administration will be stopped when an increase in systolic or diastolic BP of 10-20 mmHg above baseline is elicited. If, at any time during drug infusion, systolic blood pressure decreases below 90mmHg or increases above 160mmHg, or if the subject complains of discomfort that could be associated with blood pressure changes, the infusion will stop immediately. Specific conditions will result in arterial BRG being assessed using only NTP or PE: 1) allergy to NTP, or a systolic blood pressure (SBP) <100 will exclude the use of NTP; 2) hypersensitivity to phenylephrine products, narrow angle glaucoma or a SBP >140mmHg will exclude the use of PE. Drugs will be infused through existing venous access.

Arterial BRG will be determined as change in heart rate (HR)/change in diastolic blood pressure (DBP) during drug infusion.

Following assessment of baroreflex gain, (patients will be moved to the laboratory if the assessment was performed at bedside) patients will undergo their scheduled procedure. After the implantation of their ICD, VF induction is performed for the assessment of the defibrillation thresholds.

During the VF episodes, changes in sinus node CL measured from the stored atrial electrogram (EGM) from the implanted device will be recorded. Specifically, investigators will be measuring the average CL over the last 5 seconds before defibrillation (VF-SNCL) and will be comparing it with the average sinus node CL during the 5 seconds prior to VF induction (Baseline-SNCL). In addition, continuous BP monitoring from an existing arterial line during and following defibrillation will be stored onto a data recording system. BP recovery will be defined as the difference in mean BP during the 5 seconds before defibrillation compared with the first 30 seconds after successful defibrillation. Post-shock pacing will always be set at 40bpm in a VVI mode.

The changes in sinus node CL and BP recovery measurements will only be derived from the first successful VF induction followed by successful VF termination. The induction of non-sustained VF or VT will be considered grounds for withdrawal. On the other hand, the failure to induce VF will not be considered grounds for withdrawal.

12 Month Follow-Up: Data will be gathered from scheduled and unscheduled ICD related hospital visits for 12 months. All ICD related events will be monitored and recorded. Appropriate ICD events will be defined as all events that required anti-tachycardia pacing (ATP) or defibrillation, and which were diagnosed by 2 independent electrophysiologists as being ventricular in origin.

Study Design

Study Type:
Observational
Actual Enrollment :
33 participants
Time Perspective:
Prospective
Official Title:
Predicting Blood Pressure in Patients Following Defibrillation in Patients With an ICD Implant
Study Start Date :
Jun 1, 2005
Actual Primary Completion Date :
Jun 1, 2008
Actual Study Completion Date :
Jun 1, 2008

Arms and Interventions

Arm Intervention/Treatment
ICD Implant

All patients receiving a dual chamber ICD

Procedure: ICD Implant
Implantation of an implantable cardioverter/defibrillator
Other Names:
  • implantable cardioverter defibrillator
  • Medtronic
  • St Jude Medical
  • Boston Scientific
  • Outcome Measures

    Primary Outcome Measures

    1. Correlation of sinus node cycle length to arterial baroreflex gain [up to 12 months]

      Assessment of whether changes in sinus node cycle length during ventricular fibrillation induction correlate with arterial baroreflex gain at scheduled and unscheduled implantable cardioverter/defibrillator related hospital visits for up to 12 months

    Secondary Outcome Measures

    1. Blood pressure recovery post-defibrillation [first 30 seconds after successful defibrillation]

    2. Frequency of tachyarrhythmic events [6 months following ICD implant]

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    1. Indication for the implantation of an ICD with atrial lead placement

    2. Presence of normal sinus rhythm

    3. Age 18 or older

    Exclusion Criteria:
    1. Moderate to severe aortic stenosis

    2. Embolic stroke within the last 6 months

    Contacts and Locations

    Locations

    No locations specified.

    Sponsors and Collaborators

    • University of Utah

    Investigators

    • Principal Investigator: Mohomed Hamdan, MD, University of Utah

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    University of Utah
    ClinicalTrials.gov Identifier:
    NCT02686307
    Other Study ID Numbers:
    • 00013500
    First Posted:
    Feb 19, 2016
    Last Update Posted:
    Feb 19, 2016
    Last Verified:
    Feb 1, 2016
    Individual Participant Data (IPD) Sharing Statement:
    No
    Plan to Share IPD:
    No

    Study Results

    No Results Posted as of Feb 19, 2016