High Resolution MRI Study for Prostate Cancer

Sponsor
Cedars-Sinai Medical Center (Other)
Overall Status
Active, not recruiting
CT.gov ID
NCT03292874
Collaborator
(none)
56
1
1
74.6
0.8

Study Details

Study Description

Brief Summary

This high resolution MRI (hrMRI), along with stand MRI (sMRI) will be obtained at baseline and again in approximately 1 year in patients on prostate cancer active surveillance. Changes in lesion size and ADC values will be assessed on the serial studies. This study evaluates the hypothesis that hrMRI will detect changes that sMRI cannot detect and that these changes will correlate with prostate cancer progression as determined on prostate biopsy.

Condition or Disease Intervention/Treatment Phase
  • Diagnostic Test: high resolution MRI (hrMRI)
N/A

Detailed Description

2.0 BACKGROUND AND RATIONALE

Multiparametric MRI Multiparametric MRI combining T2-weighted, diffusion-weighted, and dynamic contrast enhanced (DCE) images is commonly employed for detection and localization of prostate lesions. Diffusion-weighted imaging (DWI) is sensitive to the diffusion of water molecules interacting with surrounding macromolecules. DWI, which provides a quantitative biological parameter called apparent diffusion coefficient (ADC) value, is a robust MRI parameter for differentiating benign and malignant prostate tissue. In fact, the latest version of the Prostate Imaging-Reporting and Data System (PI-RADS) scoring system relies almost exclusively on DWI to identify tumors in the peripheral zone, which is where the vast majority of prostate cancers form. Findings on T2 images are not used to identify cancer, and DCE images are only used to differentiate between some PI-RADS 3 and 4 lesions. In a pilot study of prostate cancer AS, DW-MRI was useful for detecting progression of Gleason score based on changes in ADC value. Tumor size is another important clinical criterion for defining low risk prostate cancer, and tumor size based on DWI has been shown to crudely predict low risk prostate cancer. However, conventional DWI using single-shot echo-planar imaging is unable to detect small tumors, low grade tumors, or small changes in tumor size on serial imaging. Approximately 20% of small, low grade tumors found in men on AS are detected on modern prostate MRI.

High Resolution MRI Investigators introduce a new three-dimensional (3D) high-resolution diffusion-weighted imaging sequence (HR-DWI), which improves image quality while conferring at least a 5-fold improvement in resolution when compared to standard two-dimensional (2D) DWI (S-DWI). This novel 3D DWI technique has been developed by our team and can be applied on existing 1.5T or 3T MRI systems. S-DWI suffers from two important limitations. a) It uses single-shot echo-planar imaging (EPI) for data acquisition, which produces magnetic susceptibility induced streaking artifacts and geometric distortions so that round objects may appear oval. b) The relatively low signal-to-noise ratio and 2D image acquisition with S-DWI limit spatial resolution, which is defined by the minimum distance between two objects required to resolve them uniquely. Our HR-DWI overcomes these limitations by using magnetization prepared, multi-shot, turbo-spin-echo acquisition, which improves signal-to-noise ratio (SNR), spatial resolution, and image quality, and eliminates geometric distortions and streaking artifacts associated with EPI.

Preliminary studies

In preliminary studies assessing the performance of our HR-DWI in a prospective pilot trial of prostate cancer AS patients, the technique could detect tumors not seen on S-DWI and measure ADC, which correlates with grade. This is important because the long-term natural history of small prostate cancers invisible to S-DWI has never been prospectively defined, in part due to lack of adequate imaging technology. In the era of molecular diagnostics and next-generation sequencing, an important step in understanding the biology of these lesions is to develop technologies to image and characterize these lesions. Importance of HR-DWI includes:

  • Better imaging will allow these lesions to be monitored serially and targeted for biopsy, providing tissue for both histologic and molecular characterization.

  • Higher resolution imaging will better delineate tumor boundaries, which can improve tumor staging and identify margins during partial-gland ablation by cryotherapy or high intensity focused ultrasound (HIFU), which was approved in 2015 by the U.S. FDA.

  • Improved imaging resolution will allow for more accurate measurement of tumor size and ADC, and detection of small changes in size or grade over time. Standard prostate DWI has poor resolution; therefore, tumor growth kinetics have never been accepted as clinical criteria for cancer progression while on AS. If tumor growth kinetics or changes in grade determined by ADC prove prognostic, AS can rely less on serial transrectal biopsies, which can lead to serious complications.

Study Design

Study Type:
Interventional
Actual Enrollment :
56 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Intervention Model Description:
Single arm, paired imagingSingle arm, paired imaging
Masking:
None (Open Label)
Primary Purpose:
Diagnostic
Official Title:
Evaluation of a Novel High-Resolution Diffusion-Weighted MRI Sequence
Actual Study Start Date :
Sep 13, 2017
Anticipated Primary Completion Date :
Dec 1, 2022
Anticipated Study Completion Date :
Dec 1, 2023

Arms and Interventions

Arm Intervention/Treatment
Other: Paired imaging

Single arm, paired imaging of high resolution MRI (hrMRI) and stand MRI (sMRI)

Diagnostic Test: high resolution MRI (hrMRI)
high resolution MRI (hrMRI) and standard MRI (sMRI) will be obtained at baseline and again in approximately 1 year in patients on prostate cancer active surveillance.

Outcome Measures

Primary Outcome Measures

  1. Evidence of prostate cancer disease progression [3 years from baseline imaging]

    evidence of disease progression as defined by any of the following: Increase in Gleason score from 3 + 3 to Gleason sum 7 on biopsy Gleason score 4+3 on biopsy Gleason sum 8-10 on biopsy > 3 Increase in number of positive cores Progression to nodal or bone involvement

Eligibility Criteria

Criteria

Ages Eligible for Study:
19 Years and Older
Sexes Eligible for Study:
Male
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Age over 18 years

  • Patients diagnosed with clinically localized prostate cancer

  • Low or Low-intermediate Risk Prostate cancer1 defined as:

  • Pre-operative prostate specific antigen (PSA) ≤ 20.0 ng/ml

  • Clinical stage cT1 or cT2

  • Gleason score 3+3 or 3+4

  • Patients choosing AS or already on AS as primary management strategy

  • No previous treatment for prostate cancer with radiotherapy, chemotherapy, or hormonal therapy

  • No contraindications for gadolinium enhanced MRI

Exclusion Criteria:
  • No exclusion criteria

Contacts and Locations

Locations

Site City State Country Postal Code
1 Cedars Sinai Medical Center Los Angeles California United States 90048

Sponsors and Collaborators

  • Cedars-Sinai Medical Center

Investigators

  • Principal Investigator: Hyung L Kim, MD, Cedars-Sinai Medical Center

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Hyung L. Kim, MD, Principal Investigator, Cedars-Sinai Medical Center
ClinicalTrials.gov Identifier:
NCT03292874
Other Study ID Numbers:
  • Pro00049177
First Posted:
Sep 26, 2017
Last Update Posted:
May 19, 2022
Last Verified:
May 1, 2022
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
Yes
Keywords provided by Hyung L. Kim, MD, Principal Investigator, Cedars-Sinai Medical Center
Additional relevant MeSH terms:

Study Results