An Investigational Scan (MRI) in Imaging Patients With Newly-Diagnosed or Recurrent Thymoma

Sponsor
M.D. Anderson Cancer Center (Other)
Overall Status
Active, not recruiting
CT.gov ID
NCT03968315
Collaborator
National Cancer Institute (NCI) (NIH)
40
1
1
144.7
0.3

Study Details

Study Description

Brief Summary

This trial studies the accuracy of a magnetic resonance imaging (MRI) scan in imaging the inside of the chest in patients with thymoma that is newly diagnosed or has come back. An MRI scan may be able to detect if and how far the tumor has spread more accurately than a standard computed tomography (CT) scan.

Condition or Disease Intervention/Treatment Phase
  • Procedure: Diaphragm Fluoroscopy
  • Procedure: Magnetic Resonance Imaging
N/A

Detailed Description

PRIMARY OBJECTIVES:
  1. To determine whether thymoma staging by MRI is as accurate as staging by CT as compared to surgical staging.
SECONDARY OBJECTIVES:
  1. To determine whether evaluation of phrenic nerve paralysis by functional MRI is as accurate as the fluoroscopic "sniff test" as compared to surgical evaluation of phrenic nerve involvement.

  2. To determine whether fast novel MRI sequences are as accurate as conventional MRI sequences for staging thymoma, when comparing to surgical staging.

OUTLINE:

Patients undergo an MRI scan over 45-60 minutes and a diaphragm fluoroscopy 30 days before surgery.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
40 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Diagnostic
Official Title:
Can MRI Replace CT in the Evaluation of Thymoma?
Actual Study Start Date :
Jun 8, 2011
Anticipated Primary Completion Date :
Jun 30, 2023
Anticipated Study Completion Date :
Jun 30, 2023

Arms and Interventions

Arm Intervention/Treatment
Experimental: Diagnostic (MRI, diaphragm fluoroscopy)

Patients undergo an MRI scan over 45-60 minutes and a diaphragm fluoroscopy 30 days before surgery.

Procedure: Diaphragm Fluoroscopy
Undergo diaphragm fluoroscopy
Other Names:
  • Sniff Test
  • Procedure: Magnetic Resonance Imaging
    Undergo MRI
    Other Names:
  • Magnetic Resonance Imaging Scan
  • Medical Imaging, Magnetic Resonance / Nuclear Magnetic Resonance
  • MRI
  • MRI Scan
  • NMR Imaging
  • NMRI
  • Nuclear Magnetic Resonance Imaging
  • Outcome Measures

    Primary Outcome Measures

    1. Accuracy of magnetic resonance imaging (MRI) staging [Up to 10 years]

      Will be compared to staging done by computed tomography (CT). McNemar's test will be used to compare the accuracy for the following five sets of comparisons: spin echo (SE) T1 compared versus (vs.) liver acquisition with volume acquisition (LAVA)+ in-phase (IP)/out-of-phase (OP), Dixon versus fast spin echo (FSE) T2, LAVA+IP/OP+Dixon vs. SET1+FSET2, LAVA+IP/OP+Dixon vs. computed tomography (CT) scan, and SET1+FSET2 vs. CT scan. A p value less than 0.05 will be defined as significant. A p value less than 0.05 will be defined as significant.

    Secondary Outcome Measures

    1. Accuracy of phrenic nerve paralysis by functional MRI [Up to 10 years]

      Will be evaluated against the fluoroscopic "sniff test" and compared to surgical evaluation of phrenic nerve involvement. The outcome is the binary indicator of whether the phrenic nerve is involved. The accuracy rate will be calculated for each of the three tested methods. And the method with the highest accuracy will be compared with the method with the medium accuracy and the method with least accuracy separately, using McNemar's test.

    2. Accuracy of fast novel MRI sequences [Up to 10 years]

      Will be evaluated against conventional MRI sequences for staging thymoma when compared to surgical staging. Will use the pathological stages as gold standard and calculate accuracy for the new shorter MRI sequences and current MRI sequences methods. Accuracy will be compared between two MRI techniques using McNemar's test. And the following five sets of comparisons will be tested: SE T1 compared vs. LAVA+ IP/OP, Dixon versus FSE T2, LAVA+IP/OP+Dixon vs. SET1+FSET2, LAVA+IP/OP+Dixon vs. CT scan, and SET1+FSET2 vs. CT scan. A p value less than 0.05 will be defined as significant.

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • All adult patients scheduled to meet with a thoracic surgeon from MD Anderson Cancer Center (ACC) for resection of newly diagnosed thymoma or thymoma recurrence in the chest and scheduled for surgery
    Exclusion Criteria:
    • Children, defined as individuals younger than 18 years old on the preoperative visit with the thoracic surgeon

    • Pregnant patients

    • Patients unable to understand the consent form

    • Patients with metal within the chest and pacemakers

    • Patients with a known allergic reaction to gadolinium, who will have their MRI performed without contrast

    • Patients with glomerular filtration rate (GFR) < 60 ml/min, who will have their MRI performed without contrast

    • Patients with an allergy to iodinated contrast material will follow departmental routine policy, that is those with anaphylaxis will have their CT performed without intravenous contrast and others will be prepped as for departmental guidelines for routine chest CT

    • Patients with abnormal renal function will have their CT study perform as per DI's iodinated contrast administration guidelines, and no contrast will be administered with GFR lower than 30 ml/min

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 M D Anderson Cancer Center Houston Texas United States 77030

    Sponsors and Collaborators

    • M.D. Anderson Cancer Center
    • National Cancer Institute (NCI)

    Investigators

    • Principal Investigator: Marcelo F Benveniste, M.D. Anderson Cancer Center

    Study Documents (Full-Text)

    None provided.

    More Information

    Additional Information:

    Publications

    None provided.
    Responsible Party:
    M.D. Anderson Cancer Center
    ClinicalTrials.gov Identifier:
    NCT03968315
    Other Study ID Numbers:
    • 2011-0360
    • NCI-2019-02643
    • 2011-0360
    • P30CA016672
    First Posted:
    May 30, 2019
    Last Update Posted:
    Jun 30, 2022
    Last Verified:
    Jun 1, 2022
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Jun 30, 2022