REMAP-VT: Repeated Endocardial Mapping for Efficacy Assessment After Catheter Ablation for Ischemic Ventricular Tachycardia

Sponsor
University Medical Centre Ljubljana (Other)
Overall Status
Not yet recruiting
CT.gov ID
NCT05713357
Collaborator
(none)
20
40.9

Study Details

Study Description

Brief Summary

Patients with ischemic ventricular tachycardia (VT) are frequently treated with radiofrequency catheter ablation. The efficacy of catheter ablation is limited for various reasons; one of those being incomplete myocardial and inhomogenous scar tissue damage due to suboptimal ablation lesions.

The aim of our study is to reassess initially ablated endocardial areas in a repeated mapping procedure. Initial lesion parameters will be studied in areas with conduction recovery at repeated mapping procedure. Also, VT inducibility will be correlated to the extent and characteristics of areas with recovered conduction.

Condition or Disease Intervention/Treatment Phase
  • Procedure: Catheter ablation

Detailed Description

Patients with ischemic ventricular tachycardia and implanted defibrillatior (ICD) will be sent to catheter ablation according to current guidelines (ESC and/or HRS). At the initial procedure the scar will be mapped with an ablation catheter and a high density catheter and all abnormal endocardial electrical potentials will be marked on a three-dimensional electro-anatomical (3DEAM) map; late potentials, local abnormal ventricular activity and decrement evoked electrical potentials. Afterwards, programed ventricular stimulation will be performed with an intent to induce sustained ventricular tachycardia. Imaging derived three-dimensional reconstructions of the ischemic scar will be used according to the operator's discretion.

All regions with abnormal endocardial electrical potentials will be ablated with an irrigated, contact force enabled catheter with a power setting of 30-50W. The aim during each energy delivery will be near-field electrical signal dissapearance or absence of myocardial capture at high energy local electrical stimulation. All ablated regions will be re-mapped during the same procedure with a high density mapping catheter. Additional ablation will be performed until all near-field electrical signals are be abolished.

The endpoint of each procedure will be absence of near-field electrical signals in the ablated areas and noninducibility of sustained ventricular tachycardia at the repeated programed ventricular stimulation.

After 1-3 months all patients will have a re-mapping procedure with a high density catheter. Programmed ventricular stimulation will be performed. If any sustained ventricular tachycardia will be induced or if any residual abnormal endocardial electrical potentials will be found in previously ablated regions, additional ablations will be performed with identical ablation settings and endpoints as in the initial procedure.

All areas previously ablated and with recovered electrical conduction will be identified, marked on the 3DEAM map and used for analysis with inclusion of ablation parameters and findings at the initial procedure and (non)inducibility of the sustained ventricular tachycardia at the repeat procedure.

Patients will be followed-up ICD interrogation at scheduled ambulatory visits or reports from emergency or other department using recorded electrocardiograms (ECG).

Study Design

Study Type:
Observational
Anticipated Enrollment :
20 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
Repeated Endocardial Mapping for Efficacy Assessment After Catheter Ablation for Ischemic Ventricular Tachycardia
Anticipated Study Start Date :
Feb 1, 2023
Anticipated Primary Completion Date :
Jul 1, 2025
Anticipated Study Completion Date :
Jul 1, 2026

Outcome Measures

Primary Outcome Measures

  1. Absence of electrical activity in previously ablated areas [3 months]

    Absent electrical activity in segments of the left ventricle ablated at initial procedure - assessed according to 17 segment model of the left ventricle, using three-dimensional electro-anatomic mapping system and high-density mapping tools. Absence of electrical activity in previously ablated segments will be regarded as a positive outcome. Presence of electrical activity will be regarded as recurrence of conduction and considered a negative outcome and a measure of procedural failure.

  2. Inducibility of ventricular tachycardia at repeat procedure [3 months]

    Inability to induce ventricular tachycardia with programed stimulation at repeat procedure will be considered a positive outcome. Inducibility of ventricular tachycardia will be considered a negative outcome and a measure of procedural failure.

Secondary Outcome Measures

  1. Recurrence of ventricular tachycardia [1 year]

    Recurrence of ventricular tachycardia detected with an implanted electrical device (ICD, CRT-D of ILR) during the follow up period

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 85 Years
Sexes Eligible for Study:
All
Inclusion Criteria:
  • ischemic heart disease,

  • sustained ventricular tachycardia,

  • implanted (or scheduled for implantation) cardiac electrical device with ability to record and store intracardiac electrograms

Exclusion Criteria:
  • nonischemic cardiomyopathy,

  • need for epicardial access to the substrate for treatment of ventricular tachycardia,

  • any severe acute organ damage beyond cardiomyopathy that could potentialy omit remapping procedure after 3 months,

  • any terminal disease with expected survival of less than one year

Contacts and Locations

Locations

No locations specified.

Sponsors and Collaborators

  • University Medical Centre Ljubljana

Investigators

  • Study Chair: Matevž Jan, MD, University Medical Centre Ljubljana

Study Documents (Full-Text)

None provided.

More Information

Publications

Responsible Party:
Matevz Jan, Electrophysiology Specialist, Principal Investigator, University Medical Centre Ljubljana
ClinicalTrials.gov Identifier:
NCT05713357
Other Study ID Numbers:
  • VT remap
First Posted:
Feb 6, 2023
Last Update Posted:
Feb 6, 2023
Last Verified:
Jan 1, 2023
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by Matevz Jan, Electrophysiology Specialist, Principal Investigator, University Medical Centre Ljubljana
Additional relevant MeSH terms:

Study Results

No Results Posted as of Feb 6, 2023