PupDyn: Pupil Dynamics and Color Vision for the Detection of Eye Diseases

Sponsor
Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts (Other)
Overall Status
Completed
CT.gov ID
NCT04909398
Collaborator
Streetlab (Other)
60
1
1
14
4.3

Study Details

Study Description

Brief Summary

The development of new oculometry techniques allows fine and dynamic measurements of pupillary diameter and use in routine clinical practice.

The preliminary results obtained with innovative devices on healthy sjuets make it possible to envisage a clinical study on a population of patients suffering from retinal pathologies.

This is a "proof of concept" study, which, if the expected results are confirmed, will make it possible to consider a study on a larger population, as well as the industrial development of a commercial device.

Condition or Disease Intervention/Treatment Phase
  • Behavioral: Dynamic pupillometry sessions
N/A

Detailed Description

This is a single-head study that will take place at the National Ophthalmology Hospital Center (CHNO) and the Vision Institute (Streetlab) and the total duration of the study is 24 months .

It is planned to include 60 participants divided into different groups:
  • 15 healthy subjects, called controls.

  • 15 patients with retinitis pigmentosa.

  • 15 patients with Leber's hereditary optic neuropathy.

  • 15 patients with Stargardt's disease.

Patients will be pre-selected on files at the CHNO clinical investigation center based on the visual assessment carried out on the day of their arrival, the doctor may suggest that they participate in the study if the inclusion criteria are respected.

The control subjects will be recruited thanks to the database of the Vision Institute at Streetlab.

Study Design

Study Type:
Interventional
Actual Enrollment :
60 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Other
Official Title:
New Methods of Dynamic Pupillometrics in Subjects With Visual and Color Vision Pathologies for the Detection, Functional Diagnosis and Follow-up of These Pathologies
Actual Study Start Date :
Mar 22, 2018
Actual Primary Completion Date :
Mar 22, 2018
Actual Study Completion Date :
May 22, 2019

Arms and Interventions

Arm Intervention/Treatment
Experimental: Dynamic pupillometry sessions

It is planned to include 60 participants divided into different groups: 15 healthy subjects, called controls. 15 patients with retinitis pigmentosa. 15 patients with Leber's hereditary optic neuropathy. 15 patients with Stargardt's disease.

Behavioral: Dynamic pupillometry sessions
The evaluation protocol will include the following steps: Installation of the subject, adaptation of the chin rest for the best comfort of the participant Calibration of the oculometer consisting of ocular fixation of 9 fixation points distributed on the stimulation screen Final validation of the eligibility of the subject in the study according to the success or not of the calibration.

Outcome Measures

Primary Outcome Measures

  1. Dynamic pupillometry sessions pupillary reflex measurement [Week 1]

    Measurement of the right eye / left eye and binocular monocular pupillary reflex: pupillary response measured for 5 seconds with 3 levels of screen luminance, each stimulation will be separated from the next by a delay of 5 seconds

  2. RAPD measurement [Week 1]

    Alternate stimulation of the right and left eye: 10 repetitions, each corresponding to the stimulation of one eye for one second.

  3. Endogenous pupillary oscillation measurement [Week 1]

    Pupil oscillation frequency, for each eye and in binocular: during this test the participants observe the stimulation screen (central fixation point) for 45 seconds during which the lumnance of the screen is calculated to be proportional to the size of the pupil in real time.

  4. Measurement of pupillary activity by frequency marking [Week 1]

    This test consists of the simultaneous presentation of 5 areas of the screen, each of which is luminance modulated at a specific frequency.

  5. Pupillary measurement of color vision [Week 1]

    In this test, 2 background colors alternate at low frequency over time. The physical luminance of one color is fixed while the other is adaptively changed during a test to reduce pupillary response.

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years to 60 Years
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • Patients with an understanding of the French language to ensure a perfect understanding of the instructions during evaluations and documents relating to their involvement in the study.
Visually impaired volunteers:

Patients must have one of three conditions: Retinitis Pigmentosa, Stargardt disease, Leber optic neuropathy.

Healthy volunteers:
  • Visual acuity of both corrected eyes (glasses) should be higher or equal 8/10th and a normal visual field.

  • Patients should not wear contact lenses (which may interfere with the recording of the pupil and eye movements)

Exclusion Criteria:
  • Pregnant or lactating women will not be able to participate in this research.

  • Participants should not be unable to personally consent.

  • Subjects should not participate in another clinical trial that may interfere with this research.

  • Inability to personally consent.

  • Subjects should not present with degenerative diseases or any other disease that could interfere with the evaluations planned during this study.

  • The subject follows a drug treatment which can cause visual disturbances, changes in pupillary kinetics or cognitive disturbances.

Secondary exclusion criteria (at the end of the inclusion visit):
  • Visually impaired subjects and controls for which calibration is not feasible.

  • Patients and control subjects having difficulty maintaining visual fixation.

  • Patients and subjects wearing corrective lenses making it impossible to record oculomotor activity with an infrared camera oculometer.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Centre Hospitalier National D'Ophtalùmologie des Quinze-Vingts Paris France 75012

Sponsors and Collaborators

  • Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts
  • Streetlab

Investigators

  • Principal Investigator: Saddek MOHAND-SAID, Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts
ClinicalTrials.gov Identifier:
NCT04909398
Other Study ID Numbers:
  • P17-05
First Posted:
Jun 1, 2021
Last Update Posted:
Jun 1, 2021
Last Verified:
May 1, 2021
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Jun 1, 2021