RETROXEN: Retrospective Study Evaluating the Impact of the XEN® Implant on Endothelial Cell Density Measured Using Specular Microscopy at 3 Years After Surgery

Sponsor
Groupe Hospitalier Paris Saint Joseph (Other)
Overall Status
Completed
CT.gov ID
NCT05904613
Collaborator
(none)
43
1
38.7
1.1

Study Details

Study Description

Brief Summary

Glaucoma is a blinding optic neuropathy affecting 80 million people worldwide, with primary open-angle glaucoma being the most common etiology. Today, the therapeutic arsenal includes drug-based hypotonizing treatments, lasers and surgery. In France, the most common surgical techniques are trabeculectomy and deep non-perforating sclerectomy (SPNP). The principle behind these filtering techniques is to lower intraocular pressure (IOP) by creating an escape route for aqueous humor from the anterior chamber (AC) of the eye into the subconjunctival space, creating a filtration bubble (FB).

A new minimally invasive treatment option has been developed to limit intra- and post-operative complications. This new technique is based on an ab interno approach, with implantation through the anterior chamber of a 6mm-long, 45µm-lumen collagen tube called XEN®. As a result, there is no dissection of the conjunctivotenone planes, as is the case in traditional surgery.

Since June 2017, surgeons have been able to use the XEN® technique in the ophthalmology department at GHPSJ.

Today, no study has yet assessed endothelial cell loss more than 2 years after this surgery. Indeed, the presence of an anterior chamber device of any type can be associated with endothelial cell loss, which increases over time well after the surgical procedure, and may require removal of the device several years after surgery.

Recent studies have investigated peripheral endothelial cell loss with other drainage systems. They show a significant decrease in peripheral endothelial cell density in relation to the implant placed in the anterior chamber. The aim of this study is to evaluate central and peripheral endothelial cell density in the long term after XEN® placement. At the visit more than 3 years after XEN® implant placement, IOP and pachymetry measurements were taken, along with a measurement of peripheral and central endothelial cell density. Corneal peripheral endothelial cell density is measured on the different quadrants of the treated eye, as well as on the controlateral eye. Measurements will be made for each eye for patients undergoing surgery on both eyes.

Condition or Disease Intervention/Treatment Phase

    Detailed Description

    Glaucoma is a blinding optic neuropathy affecting 80 million people worldwide, with primary open-angle glaucoma being the most common etiology. Today, the therapeutic arsenal includes drug-based hypotonizing treatments, lasers and surgery. In France, the most common surgical techniques for glaucoma are trabeculectomy and deep non-perforating sclerectomy (SPNP). These are two filtering techniques designed to lower intraocular pressure (IOP) by creating an escape route for aqueous humor from the anterior chamber (AC) of the eye into the subconjunctival space, creating a filtering bubble (FB). They can be performed alone, or at the same time as cataract surgery. The short-term complications encountered with these techniques are early hypotony and its attendant complications (choroidal detachment, hypotonic maculopathy, haemorrhages, etc.), the most frequent cause of which is conjunctival leakage of the bubble. In the medium term, tension rises with a deep anterior chamber are evidence of an over-tight scleral flap, which may require suture lysis. Finally, problems of excessive conjunctivotenone scarring affect 25% to 30% of patients, and are responsible for the majority of late tension increases. In the longer term, the most frequent complication is cataract. The rarest but most serious complication is infection of the BF, which occurs more frequently when the walls of the BF are ischemic or perforated. It can be complicated by endophthalmitis, which can lead to irreversible loss of visual acuity.

    A new minimally invasive treatment option has been developed to limit intra- and post-operative complications. This new technique is based on an ab interno approach, with implantation through the anterior chamber of a 6mm-long, 45µm-lumen collagen tube called XEN®. There is no need to dissect the conjunctivotenon planes, as is the case with traditional surgery.

    The geometry of the XEN® implant has been designed to prevent major hypotonia. This new technique avoids the complications associated with conjunctival dissection, while being faster and offering a standardized surgical technique. ). Today, XEN® implant placement is used in simple surgery or combined with cataract surgery for open-angle glaucoma, incipient to moderate, associated or not with a cataract, progressive and unbalanced under local hypotonizing treatment.

    Since June 2017, surgeons have been able to use the XEN® technique in the GHPSJ ophthalmology department.

    To date, no study has assessed endothelial cell loss more than 2 years after this surgery. Indeed, the presence of an anterior chamber device of any type may be associated with endothelial cell loss that increases over time, well after the operation, and may require removal of the device several years after the operation. One study showed that the microinvasive ab interno Alcon Cypass® device (a device similar to XEN®) caused significant endothelial cell loss 2 years after device implantation, and was unacceptable compared with conventional glaucoma surgery. The damage was proportional to the surface area of the implant in the anterior chamber, and led to the immediate withdrawal of the device from the market.

    Recent studies have examined peripheral endothelial cell loss with other drainage systems. They show a significant reduction in peripheral endothelial cell density in relation to the implant placed in the anterior chamber. Intracameral devices appear to have an impact on endothelial integrity. To date, no study has assessed long-term central and peripheral endothelial cell density after XEN® placement.

    At the visit more than 3 years after XEN® implantation, intraocular pressure (IOP) is measured with a Goldmann applanation tonometer, pachymetry with a NIDEK automatic refractometer and central and peripheral endothelial cell density with a NIDEK specular microscope. Peripheral corneal endothelial cell density is measured on the various ocular quadrants. The same measurements are taken on the controlateral eye. Patients undergoing surgery on both eyes receive the same measurements for each eye.

    Study Design

    Study Type:
    Observational
    Actual Enrollment :
    43 participants
    Observational Model:
    Case-Only
    Time Perspective:
    Retrospective
    Official Title:
    Retrospective Study Evaluating the Impact of the XEN® Implant on Endothelial Cell Density Measured Using Specular Microscopy at 3 Years After Surgery
    Actual Study Start Date :
    Oct 9, 2018
    Actual Primary Completion Date :
    Dec 31, 2021
    Actual Study Completion Date :
    Dec 31, 2021

    Outcome Measures

    Primary Outcome Measures

    1. assessment of long-term (>3years) central and peripheral endothelial cell density after XEN® placement. [at least 3 years after surgery]

      Difference in central and peripheral endothelial cell density between the upper nasal quadrant and the other quadrant (lower nasal, upper and lower temporal quadrant)

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years and Older
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • Male or female ≥ 18 years of age

    • French-speaking patient

    • Patients treated for primary open-angle glaucoma, normal-pressure glaucoma, pigmentary glaucoma or secondary glaucoma in the ophthalmology department of the Paris Saint-Joseph hospital group.

    • Patients who have undergone surgery with XEN® alone or in combination with cataract surgery by lens phacoemulsification, for one or both eyes.

    Exclusion Criteria:
    • Patient with any other associated ophthalmological disease, other than simple cataract already operated on or operated on simultaneously with XEN® application, with no intra- or postoperative complications

    • History of filtering surgery prior to XEN® treatment

    • Filtering surgery after XEN® treatment

    • History of vitrectomy (removal of the vitreous body from the eye)

    • Angle-closure glaucoma

    • Uveitic glaucoma (linked to inflammation which may itself have an effect on the cornea)

    • Pre-existing endothelial dystrophy, iridocorneoendothelial syndrome (ICE) (glaucoma with corneal pathology)

    • Endothelial cell count below 1000 cells

    • Patient under guardianship or curatorship

    • Patient deprived of liberty

    • Patient under court protection.

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 Groupe Hospitalier Paris Saint-Joseph Paris France 75014

    Sponsors and Collaborators

    • Groupe Hospitalier Paris Saint Joseph

    Investigators

    None specified.

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    Groupe Hospitalier Paris Saint Joseph
    ClinicalTrials.gov Identifier:
    NCT05904613
    Other Study ID Numbers:
    • RETROXEN
    First Posted:
    Jun 15, 2023
    Last Update Posted:
    Jun 15, 2023
    Last Verified:
    Jun 1, 2023
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Keywords provided by Groupe Hospitalier Paris Saint Joseph
    Additional relevant MeSH terms:

    Study Results

    No Results Posted as of Jun 15, 2023