COVID-19 MP Biomedicals SARS-CoV-2 Ag OTC: Clinical Evaluation

Sponsor
MP Biomedicals, LLC (Industry)
Overall Status
Completed
CT.gov ID
NCT05584176
Collaborator
EDP Biotech (Other)
332
4
2
1.4
83
58.8

Study Details

Study Description

Brief Summary

SARS-CoV-2 rapid antigen over the counter clinical performance evaluation

Condition or Disease Intervention/Treatment Phase
  • Device: iCura COVID-19 Antigen Rapid Home Test
  • Device: RT-PCR Test
N/A

Detailed Description

Coronavirus disease (COVID-19) is a disease caused by a newly discovered coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The SARS-CoV-2 is a β-coronavirus, which is enveloped non-segmented positive-sense RNA virus 2. It is spread by human-to-human transmission via droplets or direct contact, and infection has been estimated to have mean incubation period of 6.4 days and a basic reproduction number of 2.24-3.58. Among patients with pneumonia caused by SARS-CoV-2, fever was the most common symptom, followed by cough. On 11 March 2020, the COVID-19 outbreak was characterized as a pandemic by the WHO. Since then, over 70 million people worldwide have been infected with the virus with over 1.5 million deaths attributed to the virus. Laboratory testing for SARS-CoV-2 is currently being performed to determine if an individual has active infection via detection of viral RNA or if an individual has an immune response to the virus from a previous infection via detection of antibodies.

Specimen collection is a crucial first step in the evaluation of an individual's SARS-CoV-2 infection status. The goal of this project is to evaluate a rapid SARS-CoV-2 antigen test for over the counter (OTC) use. Study subjects under EDP supervision, either in-person or via video conference, will collect and test anterior nasal swab samples and a Study Representative will collect and ship a second nasopharyngeal swab sample for comparator PCR testing. The Rapid SARS-CoV-2 Antigen Test collection and testing methodology is viewed as a convenient and inexpensive method to test clinical specimens for SARS-CoV-2 and OTC access will improve the availability of COVD-19 testing.

The COVID-19 Antigen Rapid Test Device detects SARS-CoV-2 viral antigens through visual interpretation of color development. Anti-SARS-CoV-2 antibodies are immobilized on the test region of the nitrocellulose membrane. Anti-SARS-CoV-2 antibodies conjugated to colored particles are immobilized on the conjugated pad. A sample is added to the extraction buffer which is optimized to release the SARS-CoV-2 antigens from specimen. During testing, the extracted antigens bind to anti-SARS-CoV-2 antibodies conjugated to colored particles. As the specimen migrates along the strip by capillary action and interacts with reagents on the membrane, the complex will be captured by the anti-SARS-CoV-2 antibodies at the test region. Excess colored particles are captured at the internal control zone. The presence of a colored band in the test region indicates a positive result for the SARS-CoV-2 viral antigens, while its absence indicates a negative result. A colored band at the control region serves as a procedural control, indicating that the proper volume of specimen has been added and membrane wicking is working.

Study Design

Study Type:
Interventional
Actual Enrollment :
332 participants
Allocation:
Non-Randomized
Intervention Model:
Single Group Assignment
Intervention Model Description:
This is an open-label, prospective study to evaluate the sensitivity and specificity of the Rapid SARS-CoV-2 Antigen Test when a lay person conducts the test on themselves or another study participant. Potential subjects will be those presenting for COVID-19 testing. The study will evaluate the performance of the Rapid SARS-CoV-2 Antigen Test by comparing it to a high sensitivity EUA SARS-CoV-2 RT-PCR assay to calculate both the positive percent agreement (PPA, or sensitivity) and the negative percent agreement (NPA, or specificity).This is an open-label, prospective study to evaluate the sensitivity and specificity of the Rapid SARS-CoV-2 Antigen Test when a lay person conducts the test on themselves or another study participant. Potential subjects will be those presenting for COVID-19 testing. The study will evaluate the performance of the Rapid SARS-CoV-2 Antigen Test by comparing it to a high sensitivity EUA SARS-CoV-2 RT-PCR assay to calculate both the positive percent agreement (PPA, or sensitivity) and the negative percent agreement (NPA, or specificity).
Masking:
None (Open Label)
Primary Purpose:
Diagnostic
Official Title:
Over the Counter Rapid Antigen Test for Detection of SARS-CoV-2 Virus: Clinical Evaluation
Actual Study Start Date :
Dec 9, 2021
Actual Primary Completion Date :
Jan 21, 2022
Actual Study Completion Date :
Jan 21, 2022

Arms and Interventions

Arm Intervention/Treatment
Experimental: Subject 14-65+ years of age

Participants will have a nasopharyngeal swab sample collected by trained study site personnel for testing on a high sensitivity EUA SARS-CoV-2 RT-PCR assay to compare the result to the result of the Rapid SARS-CoV-2 Antigen Test. The participant will then self-collect or, if both are over 18, collect from another study participant an anterior nasal swab sample and test using the Rapid SARS-CoV-2 Antigen Test.

Device: iCura COVID-19 Antigen Rapid Home Test
Candidate Ag self-test kit anterior nasal specimen collection and testing will be done under the supervision of qualified site personnel in person. Comparator NP samples shall be collected at least 15 minutes prior to Ag samples with at least 15 minutes between nasal collections including collections that may occur prior to study enrollment. Comparator samples will be collected first by qualified personnel at a study site or physician's office using an FDA authorized nasopharyngeal swab collection kit and SARS-CoV-2 molecular assay.

Device: RT-PCR Test
High sensitivity RT-PCR COVID-19 Test

Experimental: At least 30 children between 2 and 13 years of age

Participants 2-13 years of age will have a nasopharyngeal swab sample collected by trained study site personnel for testing on a high sensitivity EUA SARS-CoV-2 RT-PCR assay to compare the result to the result of the Rapid SARS-CoV-2 Antigen Test. The parent or legal guardian of the child will collect an anterior nasal swab sample from the child and perform the Rapid SARS-CoV-2 Antigen Test.

Device: iCura COVID-19 Antigen Rapid Home Test
Candidate Ag self-test kit anterior nasal specimen collection and testing will be done under the supervision of qualified site personnel in person. Comparator NP samples shall be collected at least 15 minutes prior to Ag samples with at least 15 minutes between nasal collections including collections that may occur prior to study enrollment. Comparator samples will be collected first by qualified personnel at a study site or physician's office using an FDA authorized nasopharyngeal swab collection kit and SARS-CoV-2 molecular assay.

Device: RT-PCR Test
High sensitivity RT-PCR COVID-19 Test

Outcome Measures

Primary Outcome Measures

  1. Positive Percent Agreement [2 months]

    The acceptance criteria for this study is Positive Percent Agreement (PPA) greater than or equal to eighty percent in a comparison between the Rapid SARS-CoV-2 Antigen Test and RT-PCR comparator test results

  2. Negative Percent Agreement [2 months]

    The acceptance criteria for this study is Negative Percent Agreement (NPA) greater than or equal to ninety-eight percent in a comparison between the Rapid SARS-CoV-2 Antigen Test and RT-PCR comparator test results

Secondary Outcome Measures

  1. Detection of Asymptomatic Positives [2 months]

    Number of participants with a positive PCR comparator result, but reported no symptoms or epidemiological reasons to suspect COVID-19 infection within the past 14 days. This will be compared to their Rapid SARS-CoV-2 Antigen Test result to determine the ability of the Rapid SARS-CoV-2 Antigen Test to detect individuals who are infected but are not symptomatic.

Eligibility Criteria

Criteria

Ages Eligible for Study:
2 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • The study population will include subjects from 2 years old to greater than 65 years old.

  • Lay subjects who perform the test on themselves must be able to read, write, speak, and understand English.

Exclusion Criteria:
  • Subjects less than 2 years old will be excluded.

  • Participants who regularly use home diagnostic tests, such as glucose meters, or are trained medical or laboratory professionals will be excluded.

  • Persons under 14 years of age will be excluded from performing the Rapid SARS-CoV-2 Antigen Test on themselves.

  • Persons under 2 years of age will be excluded from participation.

  • Persons under 18 years of age will be excluded from performing the Rapid SARS-CoV-2 Antigen Test on another qualified participant.

Contacts and Locations

Locations

Site City State Country Postal Code
1 Accel Research DeLand Florida United States 32720
2 Daniel Sarkis Gainesville Florida United States 32607
3 Accel Research Site St. Petersburg Saint Petersburg Florida United States 33709
4 EDP Biotech Corporation Knoxville Tennessee United States 37919

Sponsors and Collaborators

  • MP Biomedicals, LLC
  • EDP Biotech

Investigators

  • Principal Investigator: Jason Liggett, PhD., EDP Biotech

Study Documents (Full-Text)

None provided.

More Information

Additional Information:

Publications

Responsible Party:
MP Biomedicals, LLC
ClinicalTrials.gov Identifier:
NCT05584176
Other Study ID Numbers:
  • EDP-SOP-TNC-014
First Posted:
Oct 18, 2022
Last Update Posted:
Oct 18, 2022
Last Verified:
Oct 1, 2022
Individual Participant Data (IPD) Sharing Statement:
No
Plan to Share IPD:
No
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of Oct 18, 2022