Actigraphy, Wearable EEG Band and Smartphone for Sleep Staging

Sponsor
SleepUp Tecnologia em Saúde Ltda (Industry)
Overall Status
Active, not recruiting
CT.gov ID
NCT04943562
Collaborator
(none)
108
1
11
9.8

Study Details

Study Description

Brief Summary

This study aims to evaluate the viability of the combined use of wearable and portable technologies for sleep staging. The results will be compared with polysomnography, in order to achieve clinical and diagnostic validation. Three domains of devices will be used: Movement sensors, wearable EEG band and smartphones

The project will be composed of two stages:

In the first stage, the use of the combination of actigraphy and EEG will be used for sleep staging in a sample of 12 healthy volunteers from 20 to 40 years old, both genders and with no sleep disorders for each combination of ACT+EEG. Considering there will two of each (thus four combinations), the final sample will be composed of 48 individuals. Once recruited, evaluated according to the inclusion and exclusion criteria and consented with the terms of this study, the participants will be referred to the sleep lab, in which they will undergo a full night type-1 in lab polysomnography, following the setup recommended by the American Academy of Sleep Medicine. Concomitantly with the polysomnography, the participants will also use the combination of ACT+EEG.

In the second stage, the most successful combination tested in the first stage will be tested in a clinical sample, composed by 60 participants from both genders, from 20 to 60 years old and with at least one sleep disorder or complaint. Among these, at least 30% of the sample should have moderate to severe insomnia, 30% should have high risk to sleep apnea and 70% should have excessive sleepiness scale. All the procedures, including the polysomnography will be performed identically to the first step.

Condition or Disease Intervention/Treatment Phase
  • Diagnostic Test: ACT+EEG

Detailed Description

This study aims to evaluate the viability of the combined use of wearable and portable technologies for sleep staging. The results will be compared with polysomnography, in order to achieve clinical and diagnostic validation. Three domains of devices will be used:

  • Movement sensors: Devices equipped with movement sensors (such as an accelerometer) able to monitor movement over the using period, converting this information in data related to the sleep-wakefulness cycle. In this category, the reference devices are the actimeters/actigraphs (ACT). Its use is recommended by the American Academy of Sleep Medicine to the diagnosis of insomnia and circadian sleep disorders, and should be used for 3 to 14 consecutive days. Other wearable devices, such as smartwatches, are also used with the same purpose, although not validated for clinical use. In this study two wearable devices with movement sensors will be used, with the following minimal specifications: accelerometer in three axes, minimal sampling rate of 25Hz, maximum weight of 100g, battery lasting at least a week and support for Bluetooth connection. The desirable criteria are: light, body temperature and hearth rhythm sensors.

  • Wearable EEG band: EEG is a mandatory feature for type-1 polysomnography and a requirement for regular sleep staging. In this project, the EEG will be used in combination with actigraphy to allow a better estimation of sleep stages. In this study two wearable EEG bands will be tested, with the following minimal specifications: dry EEG electrode (no need of paste, gel or other conductor), presented as a head band or stripe, minimal sampling rate of 500Hz, noise, high and low filters, battery lasting at least 8h, maximum weight of 200g (including the whole device) and support for Bluetooth connection.

  • Smartphones: Additionally to the movement sensors and the EEG bands, the evaluation of sleep pattern will be based on smartphone-based accelerometers. This is the most common approach among the currently available sleep tracking applications, although is the least accurate. In this project the smartphones will be equipped with SleepUp's app and its sleep tracking functionality.

The project will be composed of three stages:

In the first stage, the use of the combination of actigraphy and EEG will be used for sleep staging in a sample of 12 healthy volunteers from 20 to 40 years old, both genders and with no sleep disorders for each combination of ACT+EEG. Considering there will two of each (thus four combinations), the final sample will be composed of 48 individuals. Once recruited, evaluated according to the inclusion and exclusion criteria and consented with the terms of this study, the participants will be referred to the sleep lab, in which they will undergo a full night type-1 in lab polysomnography, following the setup recommended by the American Academy of Sleep Medicine. Concomitantly with the polysomnography, the participants will also use the combination of ACT+EEG.

In the second stage, the most successful combination tested in the first stage will be tested in a clinical sample, composed by 60 participants from both genders, from 20 to 60 years old and with at least one sleep disorder or complaint. Among these, at least 30% of the sample should have moderate to severe insomnia (as measured by the insomnia severity index), 30% should have high risk to sleep apnea (as measured by the STOP-BANG questionnaire) and 70% should have excessive sleepiness scale (as measured by the Epworth sleepiness scale). All the procedures, including the polysomnography will be performed identically to the first step.

Study Design

Study Type:
Observational [Patient Registry]
Anticipated Enrollment :
108 participants
Observational Model:
Cohort
Time Perspective:
Cross-Sectional
Official Title:
Evaluation of the Viability of Actigraphy, Wearable EEG Band and Smartphone for Sleep Staging in Comparison With Polysomnography
Actual Study Start Date :
Aug 1, 2021
Anticipated Primary Completion Date :
Jul 1, 2022
Anticipated Study Completion Date :
Jul 1, 2022

Arms and Interventions

Arm Intervention/Treatment
Healthy participants

Participants from 20 to 40 years old, from both genders and with no sleep disorders

Diagnostic Test: ACT+EEG
Combination of ACT+EEG. This is not an intervention, but rather a combination of devices to be tested regarding its diagnostic validity.

Participants with sleep disorders

one sleep disorder or complaint. Among these, at least 30% of the sample should have moderate to severe insomnia (as measured by the insomnia severity index), 30% should have high risk to sleep apnea (as measured by the STOP-BANG questionnaire) and 70% should have excessive sleepiness scale (as measured by the Epworth sleepiness scale).

Diagnostic Test: ACT+EEG
Combination of ACT+EEG. This is not an intervention, but rather a combination of devices to be tested regarding its diagnostic validity.

Outcome Measures

Primary Outcome Measures

  1. Sleep Latency [Immediately after the polysomnography.]

    Time from the beginning of the polysomnographic record until the first epoch of sleep.

  2. Total sleep time [Immediately after the polysomnography.]

    Total time of epochs staged as sleep.

  3. Sleep efficiency [Immediately after the polysomnography.]

    Percentage of sleep in relation to total record/bed time.

  4. Wake after sleep onset [Immediately after the polysomnography.]

    Total time of epochs staged as "wake" after sleep latency.

  5. Latency to REM sleep [Immediately after the polysomnography.]

    Time from sleep latency until the first epoch of REM sleep.

  6. Total time for each sleep stage [Immediately after the polysomnography.]

    Time corresponding to epochs staged as each of the sleep stages (N1, N2, N3 and REM)

  7. Percentage each sleep stage [Immediately after the polysomnography.]

    Percentage corresponding to epochs staged as each of the sleep stages (N1, N2, N3 and REM), in comparison with total sleep time.

Eligibility Criteria

Criteria

Ages Eligible for Study:
20 Years to 60 Years
Sexes Eligible for Study:
All

FIRST STAGE (Healthy volunteers)

Inclusion Criteria:
  • Age between 20 and 40 years old

  • Living in the city of São Paulo, Brazil

  • No physical or intellectual disability that prevent attending to a in-lab polysomnography or understanding its instructions.

Exclusion Criteria:
  • Excessive daytime sleepiness (as measured by the Epworth Sleepiness Scale)

  • Poor sleep quality (as measured by the Pittsburgh Sleep Quality Index)

  • Insomnia symptoms at any level (as measured by the Insomnia Severity Index)

  • Symptoms of depression (as measured by the Beck Depression Inventory)

  • High risk to sleep apnea (as measured by the Stop-Bang questionnaire)

  • Presence of sleep-related symptoms (as measured by the UNIFESP (Federal University of São Paulo sleep questionnaire)

  • Self-reported abuse of alcohol, use of abuse drugs or use of medicine that might impact the normal sleep pattern (including hypnotics, benzodiazepines, antidepressants, corticosteroids, etc).

  • Self-reported chronic diseases

  • Diagnosis of any sleep disorders during the polysomnography

SECONDS STAGE (volunteers with sleep disorders or complaints)

Inclusion Criteria:
  • Age between 20 and 40 years old

  • Living in the city of São Paulo, Brazil

  • No physical or intellectual disability that prevent attending to a in-lab polysomnography or understanding its instructions.

  • At least one sleep disorder or sleep complaint. . Among these, at least 30% of the sample should have moderate to severe insomnia (as measured by the insomnia severity index), 30% should have high risk to sleep apnea (as measured by the STOP-BANG questionnaire) and 70% should have excessive sleepiness scale (as measured by the Epworth sleepiness scale).

Exclusion criteria:
  • Absence of sleep disorders.

Contacts and Locations

Locations

Site City State Country Postal Code
1 SleepUp Tecnologia em Saúde LTDA São Caetano Do Sul São Paulo Brazil 09530-250

Sponsors and Collaborators

  • SleepUp Tecnologia em Saúde Ltda

Investigators

  • Principal Investigator: Gabriel Pires, PhD, Instituto do Sono

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
SleepUp Tecnologia em Saúde Ltda
ClinicalTrials.gov Identifier:
NCT04943562
Other Study ID Numbers:
  • SleepUp_#02
First Posted:
Jun 29, 2021
Last Update Posted:
May 17, 2022
Last Verified:
May 1, 2022
Individual Participant Data (IPD) Sharing Statement:
Undecided
Plan to Share IPD:
Undecided
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
No
Additional relevant MeSH terms:

Study Results

No Results Posted as of May 17, 2022