TEPStabil - Muscle Function and Dynamic and Postural Stability in Patients Receiving Hip or Knee Arthroplasty

Sponsor
University Hospital, Basel, Switzerland (Other)
Overall Status
Completed
CT.gov ID
NCT03860610
Collaborator
(none)
130
1
35.9
3.6

Study Details

Study Description

Brief Summary

Study 1 is to determine if muscle strength and dynamic and postural stability are compromised in patients with severe hip or knee Osteoarthritis (OA) and in patients after THA and TKA.

Study 2 is to quantify the effect of THA and TKA on muscle strength and dynamic and postural stability.

Condition or Disease Intervention/Treatment Phase
  • Diagnostic Test: Muscle strength test
  • Diagnostic Test: Dynamic stability test during level and uphill walking
  • Diagnostic Test: Postural stability test
  • Diagnostic Test: EuroQol Group Health questionnaire (EQ-5D-5L)
  • Diagnostic Test: HOOS/ KOOS
  • Diagnostic Test: Muscle activity test
  • Diagnostic Test: Passive range of motion

Detailed Description

Postural stability is defined as the ability to maintain the body's centre of gravity within the limits of stability as determined by the base of support. It is further divided in static and dynamic stability involving the ability of maintaining a base of support while standing or completing a functional Task. The importance of postural stability is accepted as a factor predicting falls and affecting the ability to perform activities of daily living.

Despite of reported strength deficits and the importance of balance, to date the potential contribution of strength deficits in patients before and after Total Hip Arthroplasty (THA) or Total Knee Arthroplasty (TKA) to compromised balance ability is unknown. Furthermore, the role of preoperative muscle function on functional outcome of THA and TKA is poorly understood. A correlation between compromised preoperative muscular function and postoperative outcome would suggest that preoperative physical therapy may be critical for preserving the muscular status and may help explain reported poorer outcome after late treatment when muscular function has already deteriorated.

The project includes two studies differing in design and primary and secondary objectives but with overlapping patient populations.

Study 1 will include all five groups, and there is only one visit by the participant (visit A).

Study 2 will include only patients from groups 3 and 4. Three assessments will be performed:

preoperatively (visit 1), 6 weeks postoperatively (visit 2) and 1 year postoperative (visit 3). Visit 1 will be identical to visit A in study 1 in these two patient groups.

Study Design

Study Type:
Observational
Actual Enrollment :
130 participants
Observational Model:
Cohort
Time Perspective:
Prospective
Official Title:
TEPStabil - Muscle Function and Dynamic and Postural Stability in Patients Receiving Hip or Knee Arthroplasty
Actual Study Start Date :
Dec 10, 2018
Actual Primary Completion Date :
Dec 7, 2021
Actual Study Completion Date :
Dec 7, 2021

Arms and Interventions

Arm Intervention/Treatment
Patient group 1 after THA

Patients who have already received a THA (N=30) for OA will be assessed 1 year postoperatively (Visit A); Interventions in this Group: 'Muscle strength test', 'Dynamic stability test during level and uphill walking', 'Postural stability test', 'EuroQol Group Health questionnaire (EQ-5D-5L)', 'HOOS/ KOOS', ' Muscle activity test', 'Passive range of motion'

Diagnostic Test: Muscle strength test
Muscle strength in knee flexion and extension and hip abduction will be tested using using a dynamometer (Biodex System 4 Pro: Biodex Medical Systems, Shirley, NY, USA)

Diagnostic Test: Dynamic stability test during level and uphill walking
Instrumented gait analysis on an overground walkway with two embedded force plates (Kistler force plate 9260AA6, Kistler AG, Winterthur, Switzerland; sampling rate 2400 Hz) and on a treadmill with an embedded plantar pressure plate (h/p/cosmos, Zebris FDM-T, Isny, Germany)

Diagnostic Test: Postural stability test
The overall stability index (OSI) will be assessed using the Biodex Balance System SD (Biodex Medical Systems, Inc., Shirley, NY, USA) and is determined by the variance in platform displacement from the horizontal plane.

Diagnostic Test: EuroQol Group Health questionnaire (EQ-5D-5L)
Overall health will be assessed using the EQ-5D-5L health questionnaire

Diagnostic Test: HOOS/ KOOS
Site specific pain and function will be assessed with the Hip Osteoarthritis Outcome Score (HOOS) and Knee Injury and Osteoarthritis Outcome Score (KOOS) depending on the affected joint (hip or knee).

Diagnostic Test: Muscle activity test
Surface electrodes (Ag/AgCl, Noraxon, U.S.A. Inc., Scottsdale, AZ, USA: 10 mm diameter, 22 mm inter-electrode distance) will be placed bilaterally on glutaeus medius, vastus medialis, semitendinosus, tibialis anterior, gastrocnemius medialis, and peroneus longus muscles. Periods of muscle activity will be defined as intensity above 2 Standard Deviation (SD) of the resting Electromyography (EMG) signal. Duration of overlapping muscle activity between agonists and antagonists normalized to one gait cycle or of a balance test, respectively, will be determined.

Diagnostic Test: Passive range of motion
Passive range of motion will be assessed for ankle plantar-/dorsiflexion, knee flexion/extension and hip flexion/extension, ab/adduction, internal/external rotation using goniometers and recorded in degrees. The range between two maxima will be recorded.

Patient group 2 after TKA

Patients who have already received a TKA (N=30) for OA will be assessed 1 year postoperatively (Visit A); Interventions in this Group: 'Muscle strength test', 'Dynamic stability test during level and uphill walking', 'Postural stability test', 'EuroQol Group Health questionnaire (EQ-5D-5L)', 'HOOS/ KOOS', ' Muscle activity test', 'Passive range of motion'

Diagnostic Test: Muscle strength test
Muscle strength in knee flexion and extension and hip abduction will be tested using using a dynamometer (Biodex System 4 Pro: Biodex Medical Systems, Shirley, NY, USA)

Diagnostic Test: Dynamic stability test during level and uphill walking
Instrumented gait analysis on an overground walkway with two embedded force plates (Kistler force plate 9260AA6, Kistler AG, Winterthur, Switzerland; sampling rate 2400 Hz) and on a treadmill with an embedded plantar pressure plate (h/p/cosmos, Zebris FDM-T, Isny, Germany)

Diagnostic Test: Postural stability test
The overall stability index (OSI) will be assessed using the Biodex Balance System SD (Biodex Medical Systems, Inc., Shirley, NY, USA) and is determined by the variance in platform displacement from the horizontal plane.

Diagnostic Test: EuroQol Group Health questionnaire (EQ-5D-5L)
Overall health will be assessed using the EQ-5D-5L health questionnaire

Diagnostic Test: HOOS/ KOOS
Site specific pain and function will be assessed with the Hip Osteoarthritis Outcome Score (HOOS) and Knee Injury and Osteoarthritis Outcome Score (KOOS) depending on the affected joint (hip or knee).

Diagnostic Test: Muscle activity test
Surface electrodes (Ag/AgCl, Noraxon, U.S.A. Inc., Scottsdale, AZ, USA: 10 mm diameter, 22 mm inter-electrode distance) will be placed bilaterally on glutaeus medius, vastus medialis, semitendinosus, tibialis anterior, gastrocnemius medialis, and peroneus longus muscles. Periods of muscle activity will be defined as intensity above 2 Standard Deviation (SD) of the resting Electromyography (EMG) signal. Duration of overlapping muscle activity between agonists and antagonists normalized to one gait cycle or of a balance test, respectively, will be determined.

Diagnostic Test: Passive range of motion
Passive range of motion will be assessed for ankle plantar-/dorsiflexion, knee flexion/extension and hip flexion/extension, ab/adduction, internal/external rotation using goniometers and recorded in degrees. The range between two maxima will be recorded.

Patient group 3 before THA

Patients with severe hip OA (N=30) scheduled to receive a THA will be assessed preoperatively (Visit 1), 12 weeks postoperative (Visit 2) and 1 year postoperative (Visit 3). Interventions in this Group: 'Muscle strength test', 'Dynamic stability test during level and uphill walking', 'Postural stability test', 'EuroQol Group Health questionnaire (EQ-5D-5L)', 'HOOS/ KOOS', ' Muscle activity test', 'Passive range of motion'

Diagnostic Test: Muscle strength test
Muscle strength in knee flexion and extension and hip abduction will be tested using using a dynamometer (Biodex System 4 Pro: Biodex Medical Systems, Shirley, NY, USA)

Diagnostic Test: Dynamic stability test during level and uphill walking
Instrumented gait analysis on an overground walkway with two embedded force plates (Kistler force plate 9260AA6, Kistler AG, Winterthur, Switzerland; sampling rate 2400 Hz) and on a treadmill with an embedded plantar pressure plate (h/p/cosmos, Zebris FDM-T, Isny, Germany)

Diagnostic Test: Postural stability test
The overall stability index (OSI) will be assessed using the Biodex Balance System SD (Biodex Medical Systems, Inc., Shirley, NY, USA) and is determined by the variance in platform displacement from the horizontal plane.

Diagnostic Test: EuroQol Group Health questionnaire (EQ-5D-5L)
Overall health will be assessed using the EQ-5D-5L health questionnaire

Diagnostic Test: HOOS/ KOOS
Site specific pain and function will be assessed with the Hip Osteoarthritis Outcome Score (HOOS) and Knee Injury and Osteoarthritis Outcome Score (KOOS) depending on the affected joint (hip or knee).

Diagnostic Test: Muscle activity test
Surface electrodes (Ag/AgCl, Noraxon, U.S.A. Inc., Scottsdale, AZ, USA: 10 mm diameter, 22 mm inter-electrode distance) will be placed bilaterally on glutaeus medius, vastus medialis, semitendinosus, tibialis anterior, gastrocnemius medialis, and peroneus longus muscles. Periods of muscle activity will be defined as intensity above 2 Standard Deviation (SD) of the resting Electromyography (EMG) signal. Duration of overlapping muscle activity between agonists and antagonists normalized to one gait cycle or of a balance test, respectively, will be determined.

Diagnostic Test: Passive range of motion
Passive range of motion will be assessed for ankle plantar-/dorsiflexion, knee flexion/extension and hip flexion/extension, ab/adduction, internal/external rotation using goniometers and recorded in degrees. The range between two maxima will be recorded.

Patient group 4 before TKA

Patients with severe knee OA (N=30) scheduled to receive a TKA will be assessed preoperatively (Visit 1), 12 weeks postoperative (Visit 2) and 1 year postoperative (Visit 3). Interventions in this Group: 'Muscle strength test', 'Dynamic stability test during level and uphill walking', 'Postural stability test', 'EuroQol Group Health questionnaire (EQ-5D-5L)', 'HOOS/ KOOS', ' Muscle activity test', 'Passive range of motion'

Diagnostic Test: Muscle strength test
Muscle strength in knee flexion and extension and hip abduction will be tested using using a dynamometer (Biodex System 4 Pro: Biodex Medical Systems, Shirley, NY, USA)

Diagnostic Test: Dynamic stability test during level and uphill walking
Instrumented gait analysis on an overground walkway with two embedded force plates (Kistler force plate 9260AA6, Kistler AG, Winterthur, Switzerland; sampling rate 2400 Hz) and on a treadmill with an embedded plantar pressure plate (h/p/cosmos, Zebris FDM-T, Isny, Germany)

Diagnostic Test: Postural stability test
The overall stability index (OSI) will be assessed using the Biodex Balance System SD (Biodex Medical Systems, Inc., Shirley, NY, USA) and is determined by the variance in platform displacement from the horizontal plane.

Diagnostic Test: EuroQol Group Health questionnaire (EQ-5D-5L)
Overall health will be assessed using the EQ-5D-5L health questionnaire

Diagnostic Test: HOOS/ KOOS
Site specific pain and function will be assessed with the Hip Osteoarthritis Outcome Score (HOOS) and Knee Injury and Osteoarthritis Outcome Score (KOOS) depending on the affected joint (hip or knee).

Diagnostic Test: Muscle activity test
Surface electrodes (Ag/AgCl, Noraxon, U.S.A. Inc., Scottsdale, AZ, USA: 10 mm diameter, 22 mm inter-electrode distance) will be placed bilaterally on glutaeus medius, vastus medialis, semitendinosus, tibialis anterior, gastrocnemius medialis, and peroneus longus muscles. Periods of muscle activity will be defined as intensity above 2 Standard Deviation (SD) of the resting Electromyography (EMG) signal. Duration of overlapping muscle activity between agonists and antagonists normalized to one gait cycle or of a balance test, respectively, will be determined.

Diagnostic Test: Passive range of motion
Passive range of motion will be assessed for ankle plantar-/dorsiflexion, knee flexion/extension and hip flexion/extension, ab/adduction, internal/external rotation using goniometers and recorded in degrees. The range between two maxima will be recorded.

Healthy control group

Age-matched healthy control subjects (N=30);Interventions in this Group: 'Muscle strength test', 'Dynamic stability test during level and uphill walking', 'Postural stability test', 'EuroQol Group Health questionnaire (EQ-5D-5L)', 'HOOS/ KOOS', ' Muscle activity test', 'Passive range of motion'

Diagnostic Test: Muscle strength test
Muscle strength in knee flexion and extension and hip abduction will be tested using using a dynamometer (Biodex System 4 Pro: Biodex Medical Systems, Shirley, NY, USA)

Diagnostic Test: Dynamic stability test during level and uphill walking
Instrumented gait analysis on an overground walkway with two embedded force plates (Kistler force plate 9260AA6, Kistler AG, Winterthur, Switzerland; sampling rate 2400 Hz) and on a treadmill with an embedded plantar pressure plate (h/p/cosmos, Zebris FDM-T, Isny, Germany)

Diagnostic Test: Postural stability test
The overall stability index (OSI) will be assessed using the Biodex Balance System SD (Biodex Medical Systems, Inc., Shirley, NY, USA) and is determined by the variance in platform displacement from the horizontal plane.

Diagnostic Test: EuroQol Group Health questionnaire (EQ-5D-5L)
Overall health will be assessed using the EQ-5D-5L health questionnaire

Diagnostic Test: HOOS/ KOOS
Site specific pain and function will be assessed with the Hip Osteoarthritis Outcome Score (HOOS) and Knee Injury and Osteoarthritis Outcome Score (KOOS) depending on the affected joint (hip or knee).

Diagnostic Test: Muscle activity test
Surface electrodes (Ag/AgCl, Noraxon, U.S.A. Inc., Scottsdale, AZ, USA: 10 mm diameter, 22 mm inter-electrode distance) will be placed bilaterally on glutaeus medius, vastus medialis, semitendinosus, tibialis anterior, gastrocnemius medialis, and peroneus longus muscles. Periods of muscle activity will be defined as intensity above 2 Standard Deviation (SD) of the resting Electromyography (EMG) signal. Duration of overlapping muscle activity between agonists and antagonists normalized to one gait cycle or of a balance test, respectively, will be determined.

Diagnostic Test: Passive range of motion
Passive range of motion will be assessed for ankle plantar-/dorsiflexion, knee flexion/extension and hip flexion/extension, ab/adduction, internal/external rotation using goniometers and recorded in degrees. The range between two maxima will be recorded.

Outcome Measures

Primary Outcome Measures

  1. Muscle strength (Study 1) [single point measurement at Visit A (week 0)]

    For the knee, maximum isokinetic flexion and extension torques will be collected between full extension and 90° flexion at a movement speed of 60°/s (5 repetitions) and 240°/s (5 repetitions).For the hip, maximum abduction torques will be measured isometrically (5 repetitions) in a standing position. Maximum joint torques in each movement direction will be recorded for each joint and normalized to body weight (study group 1 to 5)

  2. Change in Muscle strength (Study 2) [Three assessments will be performed: preoperatively (visit 1), 6 weeks postoperatively (visit 2) and 1 year postoperative (visit 3).]

    For the knee, maximum isokinetic flexion and extension torques will be collected between full extension and 90° flexion at a movement speed of 60°/s (5 repetitions) and 240°/s (5 repetitions).For the hip, maximum abduction torques will be measured isometrically (5 repetitions) in a standing position. Maximum joint torques in each movement direction will be recorded for each joint and normalized to body weight (study group 3 and 4)

  3. Postural stability (Study 1) [single point measurement at Visit A (week 0)]

    The overall stability index (OSI) will be assessed using the Biodex Balance System SD. A high stability index represents the angular excursion of the subject's center of gravity and is indicative of a high degree of movement during a test (i.e.poor balance). (study group 1 to 5)

  4. Change in postural stability (Study 2) [Three assessments will be performed: preoperatively (visit 1), 6 weeks postoperatively (visit 2) and 1 year postoperative (visit 3).]

    The overall stability index (OSI) will be assessed using the Biodex Balance System SD. A high stability index represents the angular excursion of the subject's center of gravity and is indicative of a high degree of movement during a test (i.e.poor balance).(study group 3 and 4)

  5. Dynamic stability (Study 1) [single point measurement at Visit A (week 0)]

    Instrumented gait analysis on an overground walkway to compute step width for each step from a pressure plate built into the treadmill (study group 1 to 5)

  6. Change in dynamic stability (Study 2) [Three assessments will be performed: preoperatively (visit 1), 6 weeks postoperatively (visit 2) and 1 year postoperative (visit 3).]

    Instrumented gait analysis on an overground walkway to compute step width for each step from a pressure plate built into the treadmill (study group 3 and 4)

Eligibility Criteria

Criteria

Ages Eligible for Study:
30 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
Yes
Inclusion Criteria:
  • Patients with an unilateral THA or TKA, which they received for the treatment of osteoarthritis (Patient groups 1+2)

  • Patients diagnosed with unilateral OA of the knee or hip planned for a treatment with THA or TKA (Patient groups 3+4)

  • Age ≥ 30 years (Healthy control group)

Exclusion Criteria:
  • Body mass index > 35kg/m2

  • Use of walking aids

  • Neuromuscular disorders affecting gait

  • Inability to follow procedures due to psychological disorders or dementia

  • Diagnosed hip or knee OA (Healthy control group)

  • Current pain in the lower extremities or lower back (Healthy control group)

  • Rheumatoid Arthritis (Healthy control group)

  • Previous corrective osteotomy (Healthy control group)

  • Regular intake of pain medication (more than 4 times per week) (Healthy control group)

Contacts and Locations

Locations

Site City State Country Postal Code
1 Department of Orthopaedics and Traumatology, University Hospital Basel Basel Switzerland 4031

Sponsors and Collaborators

  • University Hospital, Basel, Switzerland

Investigators

  • Principal Investigator: Annegret Muendermann, Prof. Dr. MD, Department of Orthopaedics and Traumatology, University Hospital Basel

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
University Hospital, Basel, Switzerland
ClinicalTrials.gov Identifier:
NCT03860610
Other Study ID Numbers:
  • 2018-02159; ch19Muendermann
First Posted:
Mar 4, 2019
Last Update Posted:
Mar 4, 2022
Last Verified:
Mar 1, 2022
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
No
Keywords provided by University Hospital, Basel, Switzerland

Study Results

No Results Posted as of Mar 4, 2022