EXACT: Evaluation of X-ray, Acetabular Guides and CT in THR

Sponsor
University Hospitals Coventry and Warwickshire NHS Trust (Other)
Overall Status
Completed
CT.gov ID
NCT03072706
Collaborator
(none)
54
1
2
31.6
1.7

Study Details

Study Description

Brief Summary

Total hip replacement is one of the most successful surgical procedures of modern times, with over 80,000 performed each year in the UK. However, up to 5% of all primary hip replacements need to be revised within the first 10 years, and in many cases malposition of the acetabular (hip socket) component is implicated in the early failure.

The standard method of positioning the acetabular component is for the surgeon to be guided by a combination of the visible anatomical landmarks within the surgical field, and the wider environment of the operating theatre. The advent of 3D printing has led to the development of custom-made surgical guides which can be used during surgery, in order to assist the surgeon in the positioning of instruments and devices. These surgical guides are manufactured based on CT or MRI imaging, and are designed to clearly indicate to the surgeon the desired location and orientation of bony cuts and implant positions.

This study will test the hypothesis that an acetabular alignment guide combined with three-dimensional CT-based planning using the Corin OPS™ (Optimised Positioning System), provides more accurate component alignment following primary total hip replacement compared with the current standard treatment, with the aim of improving patient outcomes and reducing the risk of complications of total hip replacement.

Condition or Disease Intervention/Treatment Phase
  • Device: Corin OPS™
  • Other: 2D X-ray templating technology
N/A

Detailed Description

Total hip replacement is one of the most successful surgical procedures of modern times, with over 80,000 performed each year in the UK. The vast majority of patients experience dramatic pain relief and improvement in function for many years. Despite this, however, there remains a significant risk of complications, including dislocation, leg length discrepancy, squeaking, and premature wear and failure of the implant. It is known that such complications are more likely to occur if the acetabular component is incorrectly positioned during the surgery. Up to 5% of all primary hip replacements need to be revised within the first 10 years, and in many cases malposition of the acetabular (hip socket) component is implicated in the early failure.

The Corin OPS™ offers such a custom-made acetabular alignment guide. Prior to the patient's surgery, a CT scan of the patient's pelvis & legs is performed, and the images are used to produce a 3D computer model of the patient as they stand with a "virtual" hip replacement in place. Four additional X-rays of the pelvis and lumbar spine are also taken, with the patient adopting various predetermined "functional" positions (e.g. sitting in a chair, about to stand up). From these X-rays, the changes in the pelvic and femoral orientations can be measured for these functional positions. This data is then used to drive a simulation of the movement of the 3D computer model. The orientation of the components of the virtual hip replacement are then adjusted to optimise the biomechanical function of the joint. Once the proposed implant positions have been reviewed and approved by the surgeon, a custom-made acetabular orientation guide is 3-D printed and sterilised. During the surgery, this guide is fitted into the patient's acetabulum prior to implanting the components. Using a simple system of two sterile laser pointers, the orientation indicated by the guide can then be reproduced when the definitive acetabular component is implanted. There is no published data, however, on the accuracy of acetabular component positioning using this particular method. The standard of care in the UK for acetabular component positioning is the "freehand technique", where the surgeon is to be guided by a combination of the visible anatomical landmarks within the surgical field, and the wider environment of the operating theatre. It is important that the impact of this acetabular guide on acetabular component positioning be assessed in order to determine whether this intervention is likely to improve patient outcomes and reduce the risk of complications of total hip replacement.

Study Design

Study Type:
Interventional
Actual Enrollment :
54 participants
Allocation:
Randomized
Intervention Model:
Parallel Assignment
Intervention Model Description:
Single-centre, patient-assessor blinded, parallel-group, randomised-controlled trialSingle-centre, patient-assessor blinded, parallel-group, randomised-controlled trial
Masking:
Single (Outcomes Assessor)
Masking Description:
The patient assessor will be blinded to the patients' group allocation
Primary Purpose:
Device Feasibility
Official Title:
Evaluation of X-ray, Acetabular Guides and CT in THR
Actual Study Start Date :
Nov 7, 2017
Actual Primary Completion Date :
Jun 26, 2020
Actual Study Completion Date :
Jun 26, 2020

Arms and Interventions

Arm Intervention/Treatment
Active Comparator: Standard group

2D X-ray templating technology

Other: 2D X-ray templating technology
Standard care where hip replacement is planned using 2D X-ray templating software
Other Names:
  • Standard Care
  • Experimental: Corin OPS™

    Corin Optimised Positioning System (OPS) Dynamic Hip Analysis

    Device: Corin OPS™
    The OPS Dynamic Hip Analysis is a computer software package used to generate simulations of a total joint replacement from patient imaging. The dynamic simulation is used for operative planning, including implant selection, sizing and placement; and to create custom instruments or delivery specifications referencing the patient's anatomy and bio-mechanics. The simulation can also be used for the post-operative evaluation of joint performance.

    Outcome Measures

    Primary Outcome Measures

    1. Acetabular cup anteversion angle [6 weeks (+/- 2 weeks) post-surgery]

      The difference between planned and achieved acetabular cup anteversion assessed by post-operative CT scan

    Secondary Outcome Measures

    1. Hip Disability & Osteoarthritis Outcome Score (HOOS) [6-weeks, 4- and 12-months post-surgery]

      Hip Disability & Osteoarthritis Outcome Score (HOOS): a validated, patient-reported measure of hip function.

    2. Oxford Hip Score [6-weeks, 4- and 12-months post-surgery]

      Oxford Hip Score: a validated, patient-reported measure of hip function

    3. EQ-5D [6-weeks, 4- and 12-months post-surgery]

      EQ-5D: a standardised measure of health and economic outcome.

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years to 70 Years
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    No
    Inclusion Criteria:
    • All patients undergoing an elective primary unilateral total hip replacement (THR) under the care of an orthopaedic consultant at University Hospitals Coventry and Warwickshire NHS Trust

    • Provision of written informed consent.

    • Male or Female aged 18-70 years.

    • Able and willing to comply with all study requirements.

    Exclusion Criteria:
    • Those patients deemed by the treating clinician as unsuitable for an uncemented primary acetabular implant for reasons such as
    1. Low demand patient

    2. Osteoporosis

    3. Significant acetabular bone loss

    • Patients with significant orthopaedic deformities (eg fused knee, hip or ankle).

    • Unable to undergo planning imaging (unable to stand or sit for X-rays, or to lie in a CT scanner).

    • Patients currently receiving ionising radiation treatment or scans for other medical conditions.

    • Previous entry in this trial (contralateral THR).

    • Participation in a clinical trial of an investigational medicinal product in the last 90 days.

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 University Hospitals Coventry and Warwickshire Coventry West Midlands United Kingdom CV2 2DX

    Sponsors and Collaborators

    • University Hospitals Coventry and Warwickshire NHS Trust

    Investigators

    • Principal Investigator: Richard King, MBChB, University Hospitals Coventry and Warwickshire NHS Trust

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    University Hospitals Coventry and Warwickshire NHS Trust
    ClinicalTrials.gov Identifier:
    NCT03072706
    Other Study ID Numbers:
    • RK174116
    First Posted:
    Mar 7, 2017
    Last Update Posted:
    Aug 11, 2020
    Last Verified:
    Aug 1, 2020
    Individual Participant Data (IPD) Sharing Statement:
    No
    Plan to Share IPD:
    No
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Keywords provided by University Hospitals Coventry and Warwickshire NHS Trust

    Study Results

    No Results Posted as of Aug 11, 2020