Outcomes of Ablation of Unresectable Pancreatic Cancer Using the NanoKnife Irreversible Electroporation (IRE) System

Sponsor
University of Maryland, Baltimore (Other)
Overall Status
Recruiting
CT.gov ID
NCT02041936
Collaborator
(none)
12
1
1
104
0.1

Study Details

Study Description

Brief Summary

The purpose of this study is to evaluate the short and intermediate term outcomes of the NanoKnife Irreversible Electroporation System when used to treat unresectable pancreatic cancer. In addition, the study will evaluate the efficacy of this device in treating symptoms of unresectable pancreatic cancer. The NanoKnife, System has been commercially available since 2009, and is FDA-approved to treat soft tissue tumors. The NanoKnife System has received FDA clearance for the surgical ablation of soft tissue. It has not received clearance for the therapy or treatment of any specific disease or condition.

Irreversible electroporation (IRE) has the potential to dramatically widen the treatment options for patients with pancreatic cancer. It provides a minimally invasive procedure that could potentially avoid radical surgery for smaller lesions, and it could potentially offer palliation of symptoms such as pain, gastric outlet obstruction and jaundice in patients with locally advanced unresectable disease.

Condition or Disease Intervention/Treatment Phase
  • Device: NanoKnife IRE System
N/A

Detailed Description

The prognosis for pancreatic cancer is dismal, with a five-year survival rate of 4.9%. Current treatment options include surgical resection, chemotherapy and radiation. Only 15% percent of pancreatic cancers are considered resectable at the time of diagnosis. Current chemotherapeutic options are limited, as pancreatic adenocarcinoma is poorly responsive to chemotherapy. Radiofrequency ablation of the pancreas in the setting of locally advanced unresectable disease has been described in a few case series1-6, but implementation of that technology is limited by concerns over thermal injury to adjacent organs and vessels. With 42,470 new cases of pancreatic cancer diagnosed annually in the US and given that pancreatic cancer is expected to claim 35,240 lives this year in the US7, it is the fourth leading cause of cancer death in the Unites States. This information supports the notion that there is an unquestionable need for novel therapeutic strategies for the treatment of this disease.

Irreversible electroporation (IRE) has the potential to dramatically widen the treatment options for patients with pancreatic cancer. It provides a minimally invasive procedure that could potentially avoid radical surgery for smaller lesions, and it could potentially offer palliation of symptoms such as pain, gastric outlet obstruction and jaundice in patients with locally advanced unresectable disease. Preliminary studies of IRE in the liver and prostate have demonstrated that structures such as bile ducts, ejaculatory ducts, neurovascular bundles, blood vessels, and the urethra heal normally after ablation, suggesting that vessels and ducts within and around the pancreas may also be heal normally. Collagen matrix during treatment with IRE is not destroyed thus allowing for a structure to heal normally. There is no evidence that nerve ganglion are damaged.

Heat based ablative therapy in the pancreas has the potential for unique complications. Pancreatic necrosis is believed to play a role in creating a potentially life-threatening systemic inflammatory response in patients with severe acute pancreatitis8, 9 and the presence of free active pancreatic enzymes is believed to contribute to the inflammatory cascade of acute pancreatitis. Irreversible electroporation could potentially cause both pancreatic necrosis and the release of active pancreatic enzymes. Additionally, the pancreas surrounds or abuts several vital structures, including the common bile duct, the pancreatic duct, the superior mesenteric artery and vein (SMA and SMV), the portal vein, the stomach, and the duodenum. IRE as a non-thermic ablative modality has the potential to achieve pancreatic ablation with respect of the surrounding vascular and ductal structures.

Electroporation is a technique that increases cell membrane permeability by momentarily changing the transmembrane potential and subsequently disrupting the lipid bi-layer integrity to allow transportation of molecules across the cell membrane via nano-size pores. This process - when used in a reversible fashion - has been used in research for drug or gene delivery into cells.

Irreversible electroporation (IRE) is a method to induce irreversible disruption of cell membrane integrity (loss of cell homeostasis) resulting in cell death without the need for additional pharmacological injury. Because IRE is a non-thermal technique, changes associated with perfusion-mediated tissue cooling (or heating) are not relevant. While cells in the ablation region are destroyed, the underlying extracellular matrix is not damaged thus allowing tissues in the ablation zone to heal normally.

IRE is administered under general anesthesia with administration of atracurium, cis-atracurium, pancuronium or an equivalent neuromuscular blocking agent. This is mandatory to prevent undesirable muscle contraction.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
12 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Treatment
Official Title:
Evaluation of the Short and Intermediate Term Outcomes of Ablation of Locally Advanced Unresectable Pancreatic Cancer Using the NanoKnife Irreversible Electroporation (IRE) System - A Prospective Study
Study Start Date :
Apr 1, 2014
Anticipated Primary Completion Date :
Dec 1, 2022
Anticipated Study Completion Date :
Dec 1, 2022

Arms and Interventions

Arm Intervention/Treatment
Experimental: NanoKnife IRE System

Device: NanoKnife IRE System

Outcome Measures

Primary Outcome Measures

  1. Number of Participants with Adverse Events as a Measure of Safety and Tolerability [1, 2, 4, 7, 14, 21 and 30 days and 3, 6, 9, 12, 15, 18, 21, and 24 months post-IRE procedure]

Secondary Outcome Measures

  1. Pain Scores on the Visual Analogue Score (VAS) [1, 4, 7, 14, 21, and 30 days and 3, 6, 9, 12, 15, 18, 21, and 24 months post-IRE procedure]

  2. Quality of Life on the EORTC QLQ-PAN26 and EORTC QLQ-C30 [1, 4, 7, 14, 21, and 30 days and 3, 6, 9, 12, 15, 18, 21, and 24 months post-IRE procedure]

Eligibility Criteria

Criteria

Ages Eligible for Study:
18 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  • Male or female

  • 18 years of age

  • Must be found to have locally advanced unresectable disease following standard chemotherapy ± radiotherapy as demonstrated with either CT/MRI imaging and surgical evaluation, and not have taken any chemotherapy/radiotherapy within 5 weeks of treatment with the NanoKnife IRE System

  • Must have an INR < 1.5

  • Are willing and able to comply with the protocol requirements

  • Are able to comprehend and willing to sign an informed consent form

Exclusion Criteria:
  • A baseline creatinine reported as > 2.0 mg/dL

  • Have any reported baseline lab values with a grade 3 or 4 toxicity as defined by the CTCAE Version 3.0

  • Inability to stop antiplatelet and coumadin therapy for 7 days prior to and 7 days post treatment with the NanoKnife System

  • Tumor size not measurable

  • Known history of contrast allergy that cannot be medically managed

  • Known hypersensitivity to the metal in the electrodes (stainless steel 304L) that cannot be medically managed

  • Unable to be treated with a muscle blockade agent (e.g. pancuronium bromide, atracurium, cisatracurium, etc.)

  • Women who are pregnant or currently breast feeding

  • Women of childbearing potential who are not utilizing an acceptable method of contraception

  • Have taken an investigational agent within 30 days of visit 1

  • Have implanted cardiac pacemakers or defibrillators

  • Have implanted electronic devices or implants with metal parts in the immediate vicinity of a lesion

  • Have a history of epilepsy or cardiac arrhythmia (atrial or ventricular fibrillation)

  • Have a recent history of myocardial infarction (within the past 2 months)

  • Have Q-T intervals greater than 550 ms unless treated with an Accysync Model 72 synchronization system controlling the NanoKnife system's output pulses

  • Evidence of distant metastases of stage IV

  • Have taken any chemotherapeutic agent within 5 weeks of treatment with the NanoKnife Irreversible Electroporation (IRE) System

  • Receive non-conventional fractionation schedules, such as stereotactic radiation (5 fractions or less) or received higher than 54 Gray (Gy) delivered conventionally

Contacts and Locations

Locations

Site City State Country Postal Code
1 University of Maryland Medical Center Baltimore Maryland United States 21201

Sponsors and Collaborators

  • University of Maryland, Baltimore

Investigators

  • Principal Investigator: Cherif Boutros, MD, University of Maryland, Baltimore

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
Cherif Boutros, Associate Professor - Surgical Oncology, University of Maryland, Baltimore
ClinicalTrials.gov Identifier:
NCT02041936
Other Study ID Numbers:
  • HP-00052144
First Posted:
Jan 22, 2014
Last Update Posted:
Mar 28, 2022
Last Verified:
Mar 1, 2022
Keywords provided by Cherif Boutros, Associate Professor - Surgical Oncology, University of Maryland, Baltimore
Additional relevant MeSH terms:

Study Results