CBIA: Validity and Reliability of Commercially Available Bioelectrical Impedance Analysis Devices

Sponsor
Texas Tech University (Other)
Overall Status
Completed
CT.gov ID
NCT05026697
Collaborator
(none)
75
1
6
12.4

Study Details

Study Description

Brief Summary

The purpose of this data collection is to establish the validity and reliability of several different commercially available bioelectrical impedance analysis devices that are used to estimate body composition.

Condition or Disease Intervention/Treatment Phase

    Detailed Description

    The purpose of this data collection is to establish the validity and reliability of several different commercially available bioelectrical impedance analysis devices that are used to estimate body composition.

    This study will involve 1-2 total visits: one initial visit followed by an optional follow-up visit 12-16 weeks later. These visits will consist of body composition assessments after an overnight fast. Before the overnight fast, the individual will be asked to drink 1 liter (the equivalent of two 16.9-ounce water bottles) between the final meal of the day and the beginning of the 8-hour fasting period. At the first visit, participants will undergo dual x-ray absorptiometry (DXA; GE Lunar Prodigy), air displacement plethysmography (ADP; Cosmed Bod Pod), a 3D body scan (SizeStream SS20), and several multi- and single-frequency bioelectrical impedance analysis (BIA) assessments. The BIA assessment methods will be conducted twice. This will allow for test-retest reliability assessment of each of the BIA devices being assessed in our study. At the optional second visit, all assessment methods utilized in our laboratory will be conducted once. By comparing these values to the values from the first visit, we will be able to establish the cumulative error due to technical error and biological error (i.e. random biological differences in the participants between the two assessments). We will collect data in a similar fashion during this second visit in order to compare the changes over time between the measurements provided by the commercially available BIA devices against the changes detected by a validated 4-compartment model of body composition, which uses research-grade devices. Cumulatively, this information will provide essential data to consumers regarding both the immediate and long-term test-retest reliability as well as the validity of commercially available BIA devices such as home body fat scales.

    The commercially available BIA devices being examined in the present study includes:
    • Omron HBF-306

    • RENPHO Smart Bathroom Scale (item number: ES-26BB-B)

    • Hawanna Body Fat Scale (UPC: 791555289926)

    • Wyze Scale (SKU: WHSCL1)

    • INEVIFIT Smart Body Fat Scale (UPC: 711841680565; EAN: 0711841680565)

    • WeightWatchers Scale by Conair (model: WW721XF)

    • Tanita UM-081 (model: UM-081; EAN: 0742496801012 and 0885157966993)

    • VitaGoods FormFit Digital Scale and Body Analyzer (model: VG42252-0000)

    • Omron HBF 516 Body Composition Monitor (model: HBF-516B)

    • Seca sensa 804

    • Withings/Nokia BodyCardio Body Composition Digital Scale (model: WBS04b-Black-All-Inter)

    • Tanita BC554 IronMan Body Composition Monitor (model: BC-554)

    • Tanita BC568 InnerScan Segmental Body Composition Monitor (model: BC-568)

    • InBody H2ON Smart Full Body Composition Analyzer

    Additionally, several laboratory-grade bioimpedance technologies will be performed, including ImpediMed SFB7 bioimpedance spectroscopy and Seca mBCA 515/514 multi-frequency bioelectrical impedance analysis. Urine specific gravity will also be assessed using digital refractometry, and height will be assessed via stadiometer. As part of the ADP test, body mass estimates from a calibrated, research-grade scale will be obtained (Modified BWB-627-A, Tanita Corporation).

    The test-retest reliability of the commercially available bioelectrical impedance analysis devices will be examined through duplicate assessments. The validity of the commercially available bioelectrical impedance analysis devices will be examined as compared to the criterion laboratory methods, namely the 4-compartment model for total body composition and DXA and/or laboratory-grade segmental bioimpedance technologies for segmental body composition.

    Study Design

    Study Type:
    Observational
    Actual Enrollment :
    75 participants
    Observational Model:
    Cohort
    Time Perspective:
    Prospective
    Official Title:
    Validity and Reliability of Commercially Available Bioelectrical Impedance Analysis Devices
    Actual Study Start Date :
    Jun 9, 2021
    Actual Primary Completion Date :
    Dec 10, 2021
    Actual Study Completion Date :
    Dec 10, 2021

    Outcome Measures

    Primary Outcome Measures

    1. Body fat percentage [1 day]

      Percentage of body mass that is attributable to fat mass. This value is provided by each body composition assessment device being tested (see list of devices in Study Description).

    2. Fat-free mass [1 day]

      Calculated as body mass minus fat mass. Fat mass is equal to body mass multiplied by body fat percentage. Body fat percentage is provided by each body composition assessment device being tested (see list of devices in Study Description).

    3. Fat mass [1 day]

      Body mass multiplied by body fat percentage. Body fat percentage is provided by each body composition assessment device being tested (see list of devices in Study Description).

    Secondary Outcome Measures

    1. Segmental body fat percentage [1 day]

      Body fat percentage provided for specific body segments (i.e., trunk/torso, arms, and legs). These values are provided by some, but not all, of the body composition assessment devices being tested (see list of devices in Study Description).

    2. Segmental fat-free mass [1 day]

      Fat-free mass (i.e., body mass minus fat mass) provided for specific body segments (i.e., trunk/torso, arms, and legs). These values are provided by some, but not all, of the body composition assessment devices being tested (see list of devices in Study Description).

    3. Segmental fat mass [1 day]

      Fat mass provided for specific body segments (i.e., trunk/torso, arms, and legs). These values are provided by some, but not all, of the body composition assessment devices being tested (see list of devices in Study Description).

    Other Outcome Measures

    1. Body mass [1 day]

      Body mass estimates provided by the scale of each body composition assessment device (see list of devices in Study Description).

    2. Total body water [1 day]

      Mass of total body water. These values are provided by some, but not all, of the body composition assessment devices being tested (see list of devices in Study Description).

    3. Visceral fat [1 day]

      Mass of visceral fat. These values are provided by some, but not all, of the body composition assessment devices being tested (see list of devices in Study Description).

    4. Bone mineral mass [1 day]

      Mass of bone mineral; These values are provided by some, but not all, of the body composition assessment devices being tested (see list of devices in Study Description).

    Eligibility Criteria

    Criteria

    Ages Eligible for Study:
    18 Years to 50 Years
    Sexes Eligible for Study:
    All
    Accepts Healthy Volunteers:
    Yes
    Inclusion Criteria:
    • Between the ages of 18 and 50

    • Generally healthy (defined as an absence of any disease or medical condition which could potentially result in abnormal body composition, including but not limited to musculoskeletal or metabolic diseases)

    • Weight-stable (defined as no change in body mass >5 pounds in the past month)

    Exclusion Criteria:
    • Failing to meet any of the aforementioned inclusion criteria or self-reporting a body composition abnormality (due to medical condition, lifestyle practices, etc.)

    • Height greater than 75.5 inches (due to height limitation of DXA scanner)

    • Weight greater than 330 pounds (due to weight limitation of some of the devices used)

    • Presence of facial hair longer than 1/2 inch (and unwillingness to shave) or self-report of large amounts of body hair due to the impact of hair on Bod Pod body volume estimates

    • Presence of pacemaker or any electrical device (due to electrical currents administered by bioimpedance devices)

    • Amputation of limb, implantation of a meaningful amount metal (e.g., full joint replacement), or physical deformity large enough to invalidate traditional body composition assessments

    Contacts and Locations

    Locations

    Site City State Country Postal Code
    1 Department of Kinesiology & Sport Management Lubbock Texas United States 79409

    Sponsors and Collaborators

    • Texas Tech University

    Investigators

    • Principal Investigator: Grant Tinsley, PhD, Texas Tech University

    Study Documents (Full-Text)

    None provided.

    More Information

    Publications

    None provided.
    Responsible Party:
    Texas Tech University
    ClinicalTrials.gov Identifier:
    NCT05026697
    Other Study ID Numbers:
    • IRB2021-107
    First Posted:
    Aug 30, 2021
    Last Update Posted:
    Aug 9, 2022
    Last Verified:
    Aug 1, 2022
    Individual Participant Data (IPD) Sharing Statement:
    Undecided
    Plan to Share IPD:
    Undecided
    Studies a U.S. FDA-regulated Drug Product:
    No
    Studies a U.S. FDA-regulated Device Product:
    No
    Keywords provided by Texas Tech University

    Study Results

    No Results Posted as of Aug 9, 2022