Schulze Muscular Dystrophy Ability Clinical Study

Sponsor
AbiliTech Medical Inc. (Industry)
Overall Status
Recruiting
CT.gov ID
NCT05409079
Collaborator
Richard M. Schulze Family Foundation (Other)
35
1
1
13.1
2.7

Study Details

Study Description

Brief Summary

The primary objective of the Schulze study is to evaluate the function of the upper limbs of subjects diagnosed with neuromuscular disorders, with and without use of the Abilitech Assist device in the clinic and home environments. Functional outcomes will include documenting active range of motion and the ability to perform activities of daily living (ADLs) using the standardized Canadian Occupational Performance Measure (COPM) and the Role Evaluation of Activities of Life (REAL) assessments. Secondary objectives are to assess the safety record and report on adverse events (AEs) and parameters related to device usage, including device usage time and the time required to don/doff the device. Secondary objectives also include characterization of user upper limb performance based on etiology.

Study Design

Study Type:
Interventional
Anticipated Enrollment :
35 participants
Allocation:
N/A
Intervention Model:
Single Group Assignment
Masking:
None (Open Label)
Primary Purpose:
Treatment
Official Title:
Schulze Muscular Dystrophy Ability Clinical Study
Actual Study Start Date :
May 26, 2022
Anticipated Primary Completion Date :
Jun 30, 2023
Anticipated Study Completion Date :
Jun 30, 2023

Arms and Interventions

Arm Intervention/Treatment
Experimental: Abilitech Assist

The Abilitechâ„¢ Assist device is a passively powered orthotic device designed to support and assist the arms of patients with neuromuscular weakness for activities of daily living.

Device: Abilitech Assist
The Abilitechâ„¢ Assist is an externally worn device supported by a body frame, which is designed to support and assist the arms in activities of daily living (ADL's). The Abilitech Assist is comprised of three parts: a modular body vest that adjusts to accommodate different body sizes, a single arm orthosis that attaches to the body vest, and an external power pack and controller for tensioning the arm's internal springs to adjust the arm's level of assist. The device augments a user's native arm function to provide lift assistance. Software customizes the spring tension for the level of assist required. The user can turn the system ON/OFF and toggle and adjust the level of assist (e.g., low, medium or high assist) using a pushbutton controller.

Outcome Measures

Primary Outcome Measures

  1. Canadian Occupational Performance Measure (COPM) [Change from Baseline before device intervention (30 days), and after device intervention (60 days)]

    The Canadian Occupational Performance Measure is an evidence-based outcome measure designed to capture a client's self-perception of performance in everyday living, over time. The COPM results in two main scores - PERFORMANCE and SATISFACTION - each out of 10. PERFORMANCE and SATISFACTION scores can be generated for up to 5 individual occupational performance problems. Average PERFORMANCE and SATISFACTION scores can be calculated by summing individual problem scores and dividing by the number of problems. Change in scores for both PERFORMANCE and SATISFACTION can be calculated after a reassessment interval and a comparison of individual's score differences from Time 1 (assessment) to Time 2 (re-assessment). Increases in scores indicate improvement in task performance and satisfaction.

  2. Roll Evaluation of Activities of Life (REAL) assessment [Change from Baseline before device intervention (30 days), and after device intervention (60 days)]

    The REAL is an instrument to help professionals assess an individuals ability to care for themselves at home, at school and in the community. This assessment includes 136 total items with two domains(ADL: 78 items, IADL:58 items) that are rated using a 4-point scale (0-3) to describe whether an individual is unable, sleds, occasionally, or frequently able to complete a task. Scores are summed for each domain and compared over time with increases in scores indicating improvement in each domain.

Eligibility Criteria

Criteria

Ages Eligible for Study:
10 Years and Older
Sexes Eligible for Study:
All
Accepts Healthy Volunteers:
No
Inclusion Criteria:
  1. Subjects between 10 and 99 years of age, with onset of neuromuscular conditions that cause quadriparesis

  2. MMT score of 1-3 in the elbow, wrist and hand; and a MMT score of 2-3 in the shoulder of at least one of the subject's arms

  3. Ability of subject to raise their forearm off of their lap or laptray

  4. Willingness to comply and participate with the study protocol and attend the study sessions

  5. Ability to communicate verbally and respond to questions and commands

  6. Ability to provide informed consent

  7. Selected for participation based on investigator discretion

Exclusion Criteria:
  1. Use of invasive ventilator

  2. Open wounds or chronic pressure sores on upper extremities, neck, back or torso

  3. Significantly unstable upper extremity joints

  4. Unhealed bone fractures in the upper extremities

  5. Active rotator cuff tear, grade 2 or 3

  6. Surgical fixations limiting full passive range of motion

  7. Uncontrolled upper-limb spasticity that significantly limits normal range of motion

  8. Uncontrollable pain in the neck, shoulders or upper limbs

  9. Ability to fully raise both hands simultaneously above their head with ease as defined by the investigator

  10. Lack passive shoulder abduction of 120 degrees

  11. Lack 90 degrees of passive elbow extension

  12. Unable to follow instructions

  13. Exhibit significant behavioral problems

  14. Inability to provide consent

Contacts and Locations

Locations

Site City State Country Postal Code
1 Gillette Children's Saint Paul Minnesota United States 55101

Sponsors and Collaborators

  • AbiliTech Medical Inc.
  • Richard M. Schulze Family Foundation

Investigators

None specified.

Study Documents (Full-Text)

None provided.

More Information

Publications

None provided.
Responsible Party:
AbiliTech Medical Inc.
ClinicalTrials.gov Identifier:
NCT05409079
Other Study ID Numbers:
  • Schulze
First Posted:
Jun 8, 2022
Last Update Posted:
Jun 8, 2022
Last Verified:
Jun 1, 2022
Individual Participant Data (IPD) Sharing Statement:
Undecided
Plan to Share IPD:
Undecided
Studies a U.S. FDA-regulated Drug Product:
No
Studies a U.S. FDA-regulated Device Product:
Yes
Product Manufactured in and Exported from the U.S.:
Yes
Additional relevant MeSH terms:

Study Results

No Results Posted as of Jun 8, 2022